IDS | Event Reporting
16
Location 572 Global Split Reporting
LED On/Off Action
Explanation
Split Reporting
Option
1
ON
Bus-wired peripheral
tamper reporting
Any device connected on the keypad bus is
tampered with this option will send a report
9 OFF
2
ON
Bus-wired peripheral
fail reporting
A device on the keypad bus fails and stops
communicating a report is sent
10 OFF
3
OFF
Bus-wired peripheral
low battery reporting *
If a device is powered by a battery because of a
power failure and the battery has reached a critical
level a low battery signal is sent
11 OFF
4
ON
Wireless Detector
Battery Low
When a wireless device’s battery needs replacing a
battery low signal will be sent
12 OFF
5
OFF
Wireless Detector
Supervision fail
If a device stops communicating after a set
amount of time a supervision failure is sent
13 OFF
6
OFF
Wireless Receiver
Signal Jammed
When a signal is detected that could block signals
from the wireless detectors a jam is reported
14 OFF
7
OFF
Wireless Detector
RSSI Low
RSSI is the monitoring of signal strength from
detectors and if the signal drops below 20% a
message will be sent to alert the security company
15 OFF
8
ON
AC Restored
After AC is restored a message can be sent
16 OFF
Note: Options 9 to 16 are to select which split reporting telephone numbers to report too.
Off = split reporting group 1, On = split reporting group 2
Location 573 Global Split Reporting
LED On/Off Action
Explanation
Split Reporting
Option
1
OFF
Comms Restored
When the system is able to communicate
after a failure a restoral is sent
9 OFF
2
OFF
Comms Tamper Restore
If the lines went down and when they start
working again a restore is sent
10 OFF
3
OFF
Siren Restore
If the siren went missing and is reconnected
a restore will be sent
11 OFF
4
OFF
Battery Restore
After a battery low is reported and the
battery is changed or charged a restore will
be sent
12 OFF
5
OFF
Aux 12V Restored
After a short circuit or too much current
being drawn is fixed the fuse will restore
and send a signal
13 OFF
6
OFF
Installer Reset restored
After an installer reset required condition is
reset a signal will be sent
14 OFF
7
ON
Box tamper restored
When the box that the system is housed is
closed a restore is sent
15 OFF
8
ON
Bus device tamper restored
When the device on the keypad bus that
was tampered is restored a signal will be
sent
16 OFF
Options 9 to 16 are to select which split reporting telephone numbers to report too.