![IDS X64 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/ids/x64/x64_wireless-training_3771087015.webp)
IDS | Wireless Hardware
14
Location 304 to 335 Zone Reporting
[INSTALLER CODE] [*] [LOCATION] [*] [SUB LOC] [*] [REPORTING CODE] [*]
Loc
Sub Loc Description
Explanation
304 to
307
1 to 16
Zone alarm reporting
When the system is armed, a 24Hr zone or a panic zone is
triggered this code is reported
308 to
311
1 to 16
Zone alarm restoral
When the zone restores after being violated this code is sent
312 to
315
1 to 16
Zone tamper reporting
If the tamper monitoring option is enabled and a tamper signal
is received this code is sent
316 to
319
1 to 16
Zone tamper restoral
Once the tamper condition is corrected a restoral is sent
320 to
323
1 to 16
Zone bypass reporting
If a zone is bypassed and the alarm is armed this code is sent
to report which zones are inactive
324 to
327
1 to 16
Forced Arming
If the system is programmed to automatically bypass zones that
are violated when arming, this code is sent to alert the
monitoring company of inactive zones
328 to
331
1 to 16
Swinger shutdown
reporting
If swinger shutdown has been enabled and the alarm
automatically shuts down a zone that has violated the swinger
shutdown settings
332 to
335
1 to 16
Swing shutdown restore
The system can be set to try and restore a zone that has been
disabled by the swing shutdown option and if it is able to
restore the zone this code is sent
Location 336 to 340 Keypad Reporting
[INSTALLER CODE] [*] [LOCATION] [*] [SUB LOC] [*] [REPORTING CODE] [*]
Loc
Sub Loc Description
Explanation
336
1 to 8
Duress reporting
A user code can be programmed to send a duress signal to
alert the security company of a life threatening situation
causing the user to disarm the alarm with this code
337
1 to 8
Keypad panic
Each keypad has a panic button which when pressed can
send a code alerting the monitoring company of a situation
338
1 to 8
Fire alarm
If a fire is detected and the fire key on the keypad is pressed
this code will be reported
339
1 to 8
Medical Key reporting
A medical code can be sent alerting the monitoring company
to send an ambulance
340
1 to 8
Keypad lockout
If a code is entered incorrectly the keypad can be set to lock
for a period of time and sent this code to alert the monitoring
company
Location 342 to 373 User Reporting
[INSTALLER CODE] [*] [LOCATION] [*] [SUB LOC] [*] [REPORTING CODE] [*]
Loc
Sub Loc Description
Explanation
342 to
349
1 to 16
Close reporting
Every time a user arms the alarm this code is sent
350 to
357
1 to 16
Stay close reporting
If the user arms in stay mode this code is sent
358 to
365
1 to 16
Open reporting
Every time a user disarms the alarm this code is sent
366 to
373
1 to 16
Siren cancel reporting
When a user enters their code to cancel the siren this code is
sent
Содержание X64
Страница 1: ...X64 Wireless Training...
Страница 2: ...IDS Contents 1...
Страница 20: ...IDS Event Reporting 19...