IDS | Wireless Hardware
8
1.
Zone LEDs will be ON if the zone already has a wireless detector assigned.
The menu is now waiting for user to select to which zone to add a detector. If the user selects a pre-allocated
zone then the keypad will sound 3 error beeps and wait for a valid zone entry.
Note: Detectors may only be added on LED keypads via the tamper method.
2.
Upon valid zone selection the keypad will sound an OK (single beep) and set the zone LED selected to start
flashing. The system is now waiting for the new detector to be tampered.
When the user triggers the tamper the system will receive a notification and determine whether the detector
has already been assigned to any other zones. If this is the case the user will be notified by 3 error beeps
and the menu will keep waiting for a tamper from an unassigned detector.
If the detector has not been assigned then it will be automatically added to the system. The user will be
notified via keypad by a LONG OK beep as well as the Zone LED previously flashing will now be ON.
3.
The system will now wait for a new zone to be selected.
4.
[#] key at any time will return the user back to the sub menu selection menu.
Upon Sub menu entry the user will notice the following:
Scroll using Medical or Panic Keys, Enter with [*] key
Or enter the zone number followed by the [*] key
[#] will return user to sub menu selection entry.
Example: If zone name still default
Example: If zone name has been changed to “Main Lounge”.
Selecting a zone that is a wireless zone already, will result in an error and the user will be alerted with 3 error
beeps.
1.
Upon selecting a zone that is not already a wireless zone the user will be presented with the following.
2.
Press enter to confirm zone selection
The user must now either trigger the tamper on the detector or key in the serial number of the device.
When the user triggers the tamper the system will receive a notification and determine whether the detector
has already been assigned to any other zones. If this is the case the user will be notified by 3 error beeps
and the menu will keep waiting for a tamper from an unassigned detector.
Incorrect or pre-allocated serial numbers will also result in a 3 beep error tone and the menu will keep waiting
for a valid entry.
3.
Upon valid Serial Number entry or tamper the user will be presented with the following.
Press [*] to confirm the serial number is correct