Your HYYP Serial has successfully been synced with the HYYP
Home app.
3.
Troubleshooting
3.1.
LEDs
The HYYP IP Connect Module has 4 LEDs that you can use to view its status.
Power LED – On when the HYYP IP Connect Module has sufficient power.
Panel Comms LED – Flashes when communicating with the X-Series Panel.
Network Comms LED – Flashes when communicating on the network.
Server Auth LED – On when connected to the HYYP platform.
On power up the Network Comms and Server Auth LEDs will flash together, and once it has
made a successful connection to the HYYP platform the Server Auth LED will stay on and the
Network Comms LED will flash when it’s communicating on the network.
If the Server Auth and Network Comms LEDs continue to flash the same number then there is
an error on the HYYP IP Connect Module. You can determine the error by the amount of times
the LEDs flash.
See error numbers below:
1 – System error –
Replace unit.
2 – Can’t initialise Ethernet port.
3 – Can’t get IP address from DHCP server.
4 – Can’t connect to the Time server.
5 – Unable to log on to the HYYP platform.
6
– Unable to register on the HYYP platform.