Troubleshooting
Troubleshooting and Alarms
ISSUE
Possible Cause
Solution
No power at start up
No power to Kiln
Verify facility power to
Kiln is turned on
Main disconnect not turned on
Turn on the main
disconnect
Loose wire
A power wire may be
loose or disconnected
Fuse Blown
In the control panel
box. Located in the top
right corner. Check
fuses.
Vacuum pump does not run
No power to the pump
Vacuum Pump Motor
Starter Fault. Reset
starter.
No water to the pump
Check water
connection and flow
rate
Pump is seized
Using the seized pump
instructions. You will
need to rotate the
motor internal to the
pump.
Vacuum pump runs but no
vacuum in chamber
Door not closed
Verify there is no
obstruction between
the door gasket and
kiln.
verify the door is
closed tightly.
No water to the pump
Verify you have the
proper water pressure
going to the kiln.
On the water flow
meter. Verify the
display is showing
water flow.
Flow Meter display is reading zero
Check water flow and
pressure.
Check Rotation
Check Rotation
ISSUE
iDRY Turbo User Manual
© 2021 iDRY, LLC
33