SCREEN #1 SETUP PARAMETERS
1
Navigate to system setup screen #1
2
Press “Help” at control panel HMI (touchscreen) then press “Setup”
VACUUM
Set Point should stay at 4 unless otherwise instructed by iDRY Systems
WATER
TEMPERATURE
Set point is the maximum attainable temperature. The system will automatically control
the ramp rate depending on heat power and delta set point. It is possible that the
maximum temperature is not reached until the very end of the drying process and can
be used as a drying indicator.
HEAT POWER
Can be used to limit the temperature rise
HEAT DELTA
Set point is used to control the temperature rise. The temperature entering the kiln (IN) is
kept within this delta to the temperature exiting the kiln (OUT). This is known as the
Delta T or drop across the load. A larger Delta T means a more aggressive rise in
temperature.
VESSEL DRAIN
Cycle times can be adjusted
iDRY Turbo User Manual
© 2021 iDRY, LLC
28