1
34
2
35
3
36
4
37
5
38
6
39
7
40
8
41
9
42
10
4344
12
45
13
46
14
47
15
48
16
49
17
50
18
51
19
52
20
53
21
54
22
55
23
56
24
57
25
58
26
59
27
60
28
61
29
62
30
63
31
64
32
65
33
66
1
34
2
35
3
36
4
37
5
38
6
39
7
40
8
41
9
42
10
43
11
44 45
13
46
14
47
15
48
16
49
17
50
18
51
19
52
20
53
21
54
22
55
23
56
24
57
25
58
26
59
27
60
28
61
29
62
30
63
31
64
32
65
33
66
IDROTECH
®
Ed. 01.97
IDROTECH
®
Ed. 01.97
Fig. 8
1)
Open the tap (L) of the air compressed feeding.
2)
Open the taps (G and H Fig.7) of the correspondant connected stations.
3)
Select the manual or automatic mode with the relative selector (M) (with automatic
the unit functions with the timer (N)).
4)
Automatic mode: if you choose the automatic mode, set the programme (M) (see
the enclosed instructions).
5)
Turn the main switch (O) towards the right; the white pilot lamp (P) “Control panel
ON” turns on.
6)
Select the stations 1-2-3 using the switches Q1, Q2, Q3. According to the station
selected, the green pilot lamps will turn on (station on) R1, R2, R3.
7)
Adjust the water pressure at 3 bar (with the adjuster (V) checking the pressure gauge
8)
Adjust the air pressure at 3 bar (with the adjuster (Z) checking the pressure gauge (T).
9)
If the nebulization that is going out from the nozzles of the stations is not the one
required, operate on the air adjuster (Z) and water adjuster (V).
Give a different ratio between the two pressures than the one indicated at point 7 and 8,
so as to obtain the required nebulization (the air pressure must always be slightly higher
than the water pressure).
L
SETTING AT WORK
COMPRESSED AIR
DAILY/WEEKLY TIMER
WITH REST/WORK MODE (N)
GREEN PILOT
LAMP STATION
2 (R2)
GREEN PILOT
LAMP STATION 1
(R1)
SWITCH
STATION 1
(Q1)
WATER PRESSURE
GAUGE (S)
PRESSURE
ADJUSTER (V)
SWITCH
STATION 2
(Q2)
AIR ADJUSTER
(Z)
AIR PRESSURE
GAUGE (T)
SWITCH
STATION 3
(Q3)
MANUAL OR
AUTOMATIC
SELECTOR (M)
GREEN PILOT
LAMP
(R3)
MAIN
SWITCH (O)
WHITE PILOT LAMP (P)
CONTROL PANEL FED