Shutdown and storage of the machine 
 

 

Once  washing  operations  are  finished  turn  off  the 
machine by setting the main switch to OFF position. 

 

Subsequently  reposition  to  ON    (stand-by)  and  activate 
the steam outlet solenoid  valve by pressing the switch. 

 

Open  the  trigger  gun  and  discharge  the  steam  until  the 
complete depressurization of the boiler. 

 

Disconnect water and power supply. 

 

Wrap  steam  hose  and  electric  cable  so  they  cannot  be 
damaged. 

If  the  machine  has  to  be  stored  for  a  long  period  of 
time    empty  completely  the  boiler  with  drain  valve 

shown  in  Fig.11  and  maintain  boiler  drain  valve  opened. 
Empty also the water and detergent tanks. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Care and Maintenance 
 

Proper  maintenance  of  the  appliance  and 
regular  checks  means  safety  and  efficiency  and  
they 

also 

prevent 

problems.  

 

 

Before  any  kind    of  maintenance  switch  off  the 
machine  and  pull  the  power  plug.  Risk  of  injury 

from accidental operation of the appliance and electrical 
shock. 

 

In  case  of  storing    the  machine  in  environments 
at  temperatures  less  than  0  °  C  and  in  case  of 

transport    always  empty  the  boiler  and  tanks.  Empty 
the  glass  filter  crystals  polyphosphates  (Optional)  in 
temperatures above 40 ° C. 

 

Before any maintenance operation  do the 
following: 

 

 

Set  the  power  switch  to  1  (standby)  and  activate  the 
solenoid valve outlet steam. 

 

Open 

the 

spray 

gun 

until 

the 

complete 

depressurization of the boiler. 

 

Remove the power supply plug. 

 

Allow the appliance to cool down for at least 30min. 

 

Maintenance plan 
 

 

Clean water filter - 

Every week - 50h

 

 

Clean fuel filter - 

Monthly -150h

 

 

Clean boiler level sensors  - 

Monthly - 150h

 

 

Steam and water pipelines - 

Monthly - 150h

 

 

Steam trigger guns- 

Monthly

 

 

Cleaning the boiler - 

Every year

 

 

Ignition electrodes - 

Every year

 

 

 Replacing safety valve - 

Every 2 years

 

 

Descaling heat exchanger - 

see table.

 

 

Water  quality  control

.  If  you  use  water  with 

excessive  hardness  it  is  advised  to  carefully  follow 

the washing intervals descaling indicated in hours. 

Note: 

Contact your network provider to know the water 

hardness.

 

 

Water hardness 

° dH 

mmol/l  Hrs 

Soft 

0- 7 

0-1,3 

80 

II 

Medium 

7-14 

1,3-2,5 

50 

III 

Hard 

14-21 

2,5-3,8 

35 

IV 

Very hard 

>21 

>3,8 

25 

Содержание ASTRA EVO

Страница 1: ...e le istruzioni prima dell utilizzo WARNING read the instructions carefully before use S R L Via F Petrarca Borgoforte 127 46034 BORGO VIRGILIO MN Italy p iva e cod fiscale 02096330200 info idromatic...

Страница 2: ...2 FIG 1...

Страница 3: ...3 FIG 2 FIG 3...

Страница 4: ...4 FIG 4 FIG 5 FIG 6 FIG 7 FIG 8 FIG 9 FIG 10 FIG 11...

Страница 5: ...5 FIG 12 FIG 13 FIG 14 FIG 15 FIG 16 FIG 17 FIG 18...

Страница 6: ...rme blocco 5 Regolazione umido per uscite vapore 6 Spia presenza tensione di rete 7 Spia di stand by 8 Spia funzionamento bruciatore 9 Spia funzionamento pompa acqua 10 Spia di riserva acqua 11 Spia d...

Страница 7: ...te potenzialmente esplosive Non toccare l apparecchio con mani bagnate a piedi nudi Pneumatici e valvole d aria devono essere lavati mantenendo una distanza minima di 30 cm In caso contrario questi po...

Страница 8: ...2Vdc 230Vac assicurarsi che tale sistema sia ad onda sinusoidale e che la potenza dell inverter sia almeno 3 kW Utilizzare sistemi ad inverter consigliati dal costruttore Alimentazione idrica Si racco...

Страница 9: ...lio Rifornimento detergente versione CHEMIK Si raccomanda di leggere le specifiche del detergente da utilizzare in particolare la giusta diluizione prima di riempire il serbatoio Usare solamente deter...

Страница 10: ...to di vapore ruotare in senso antiorario la manopola sul quadro comandi Uso con detergente miscelato a vapore vers CHEMIK Per azionare il detergente premere su posizone ON l interruttore su pistola Pr...

Страница 11: ...osito della macchina in ambienti a temperature inferiori a 0 C e in caso di trasporto svuotare la caldaia e serbatoi Svuotare il bicchiere del filtro ai cristalli polifosfati Optional in caso di tempe...

Страница 12: ...tare intervento della valvola di sicurezza Si consiglia di far eseguire l operazione al personale del Servizio Assistenza Autorizzato in quanto il prodotto decalcificante pu provocare usura dei compon...

Страница 13: ...imperfetto uso dell apparecchio Il costruttore non responsabile di eventuali perdite economiche in seguito alla forzata immobilizzazione dell apparecchio ATTENZIONE Difetti quali ugelli otturati macch...

Страница 14: ...sione Controllo pulizia e regolazione elettrodi di accensione Controllo ugello gasolio Controllo della qualit del gasolio utilizzato Verifica della pressione pompa gasolio 3 Mancanza acqua in caldaia...

Страница 15: ...etergente 1 Livello detergente basso 2 Fusibile saltato 3 Problema del tubo cablato 4 Problema interruttore pistola 1 Riempire di detergente la tanica 2 Sostituire 3 Sostituire dopo aver verificato il...

Страница 16: ...to differenziale RB Rubinetto scarico serbatoio acqua RS Rubinetto scarico caldaia RD Rubinetto sfiato pompa detergente RU Rubinetto vapore umido a pannello S1 Sensore minimo caldaia S2 Sensore massim...

Страница 17: ...o L4 Spia riserva acqua L5 Spia pompa acqua L6 Spia bruciatore L7 Spia stand by funzionamento MB Motore bruciatore MP Motore pompa acqua PR Pressostato differenziale S1 Sensore livello acqua caldaia b...

Страница 18: ...GENDA U1 Interruttore ON OFF uscita vapore U2 Interruttore ON OFF uscita vapore detergente AL Alimentatore switching IN 85 240 Vac OUT 12Vdc R1 Rel pompa detergente PD Pompa vibrazione detergente F3 F...

Страница 19: ...alvole vapore diametro mm 2x3 0 2x3 0 2x3 0 2x3 0 2x3 0 2x3 0 Potenza caldaia kW 48 48 48 48 48 48 Motore pompa W 150 180 180 150 180 180 Motore bruciatore W 110 110 110 110 110 110 Pressione gasolio...

Страница 20: ...CE Direttiva sui rifiuti di apparecchiature elettriche ed elettroniche RAEE 2011 65 CE Direttiva sulla restrizione di sostanze pericolose RoHS Norme tecniche armonizzate applicate EN 12100 1 EN 12100...

Страница 21: ...ato differenziale Termosato di sicurezza Controllo rubinetto vapore umido Controllo integrit cavo elettrico di alimentazione Controllo spina Controllo messa a terra Controllo interruttori generale e a...

Страница 22: ...ato differenziale Termosato di sicurezza Controllo rubinetto vapore umido Controllo integrit cavo elettrico di alimentazione Controllo spina Controllo messa a terra Controllo interruttori generale e a...

Страница 23: ...23...

Страница 24: ...team outlet switch Left 3 Steam outlet switch Right 4 Alarm block lamp 5 Wet dry regulation knob 6 Power supply voltage lamp 7 Stand by Functioning lamp 8 Burner lamp 9 Water pump lamp 10 Water reserv...

Страница 25: ...rbidden to use the machine in a potentially explosive or hazardous areas Do not touch the appliance with wet hands barefoot Tires and air valves should be washed maintaining a minimum distance of 30 c...

Страница 26: ...ems recommended by the manufacturer Water connection We recommend the use of demineralized water Do not use pure distilled water or treatment of it that can altering and diminishing the conductivity T...

Страница 27: ...rculation pump Supply detergent tank vers CHEMIK Please read the specifications of the detergent to be used in particular the right dilution before filling the tank Use only cleaning fluids Avoid acid...

Страница 28: ...unter clockwise the knob on the control panel Use with detergent mixed with steam Vers CHEMIK To activate the detergent pump press the ON switch on the gun Press the trigger to wash with steam and det...

Страница 29: ...oring the machine in environments at temperatures less than 0 C and in case of transport always empty the boiler and tanks Empty the glass filter crystals polyphosphates Optional in temperatures above...

Страница 30: ...connected to the device to prevent intervention of the safety valve It is advisable this procedure to be done only by Authorized Service as the descaling product may cause wear Dispose the descaling...

Страница 31: ...age to persons or property caused by bad installation or incorrect use of the machine The manufacturer is not responsible for any economic losses as a result of the forced immobilization of the device...

Страница 32: ...Check clean set ignition electrodes Clean replace diesel nozzle Verity diesel quality Verify set diesel pressure 3 Boiler water shortage Sensor S2 doesn t detect water within 120sec from pump startin...

Страница 33: ...pump fuse blown 3 Cabled hose failure connections 4 Steam trigger switch failure 1 Refill detergent tank 2 Replace 3 Replace verify first connections of CN1 CN3 4 Replace The detergent pump works but...

Страница 34: ...ential pressure switch RB Water tank discharge valve RS Boiler discharge valve RD Detergent pump discharge valve RU Wet dry steam valve S1 Boiler probe sensor low S2 Boiler probe sensor High S3 Water...

Страница 35: ...lamp L4 Water tank shortage lamp L5 Water pump lamp L6 Burner lamp L7 Stand by functioning lamp MB Burner fan motor MP Water pump motor PR Differential pressure switch S1 Boiler probe sensor low S2 Bo...

Страница 36: ...ions OPTIONAL LEGEND U1 ON OFF switch for steam outlet left U2 ON OFF switch for steam detergent outlet right AL Switching power supply IN 85 240 Vac OUT 12Vdc R1 Detergent pump Relais PD Detergent vi...

Страница 37: ...ter mm 2x3 0 2x3 0 2x3 0 2x3 0 2x3 0 2x3 0 Boiler power kW 48 48 48 48 48 48 Water pump motor W 150 180 180 150 180 180 Burner fan W 110 110 110 110 110 110 Diesel pressure Bar 11 5 12 11 5 12 11 5 11...

Страница 38: ...ctrical and electronic equipment WEEE 2011 65 EC Restriction of Hazardous Substances Directive RoHS Applied harmonized standards EN 12100 1 EN 12100 2 EN 60335 1 2013 EN 60335 2 79 2013 EN 12952 4 EN...

Страница 39: ...s DIfferential pressure switch Safety thermostat Wet steam valve check Electrical power cord check Power plug check Protection earthing checked Control Swicthes Boiler Water probe sensors check Boiler...

Страница 40: ...s DIfferential pressure switch Safety thermostat Wet steam valve check Electrical power cord check Power plug check Protection earthing checked Control Swicthes Boiler Water probe sensors check Boiler...

Страница 41: ...41...

Отзывы: