background image

29

 

The integrity and insulation of the electric cable and equipment 

MUST BE

 checked, be-

cause the work environment is necessarily exposed to water and humidity conditions 

that preclude the natural system insulation;

 

DO NOT 

pull the cord to remove the plug; 

 

DO NOT

 touch the plug with wet hands or feet! 

 

Avoid accidental operation. You MUST place the switch OFF before inserting or removing 

the plug from the socket;

 

DO NOT

 use the machine if the cable is damaged or worn; disconnect the device from the 

network and contact an authorized service center; 

 

In dangerous situations, the machine should be stopped immediately.

 

DO NOT

 install the machine near flammable materials (expecially on environments with 

airborne particles: plastics, resins, acids, inks, etc.);

 

DO NOT

 use paints, acids, solvents, oily or very dense liquids, and so on;

 

The machine 

MUST BE

 used by a properly trained single operator;

 

DO NOT

 remove or tamper with the safety devices and protection installed on the ma-

chine;

 

DO NOT

 use the machine in the presence of unauthorized person or persons who are not 

wearing suitable protective garments;

 

It is RECOMMENDED not to place the machine on ramps or sloped floor, possibly remem-

ber to lock the wheels with the appropriate mechanisms;

 

ARE OBLIGED

 to place the machine on a flat and level for both installation and storage;

 

During the handling of the machine on sloping surfaces, potholes or on particularly un-

stable ground there is a risk that the machine chutes. The movement of the machine 

under the circumstances described above 

MAY RESULT

 in malfunction due to sudden 

impact or overturning;

 

If the machine will be put outside good precautions must be taken in order to 

PREVENT

 

the dangerous effect of weather conditions.

 

KEEP

 the machine clean and tidy;

 

Absolutely 

NO MOVE

 the machine during operation;

 

Absolutely 

NO MOVE

 the machine when connected to mains water and electricity

 

The table (see par. 3.2) 

MUST BE

 used to place objects to a total load under 5 kg. 

DO NOT

 

sit or rest

2.7 SYMBOLS
In this manual the symbols depicted describe important functions of the machine for the 

installation, and for the use and disposal. For correct and safe use of the machine the ope-

rator must read carefully all parts of this manual paying special attention to the warning 

symbols and manufacturer’s plate.
PAY ATTENTION TO SAFETY IN THE WORKPLACE!

FOLLOW THE INSTRUCTIONS DISPLAYED ON THE WARNING SIGNS. FAILURE TO DO SO MAY 

CAUSE SEVERE INJURY OR ENDANGER PERSONAL SAFETY. ENSURE THAT THE SIGNS ARE 

PRESENT AND LEGIBLE. IF THEY ARE NOT, THEY SHOULD BE FITTED OR REPLACED.
THIS MANUAL MUST BE READ BEFORE USING OR CARRYING OUT MAINTENANCE OR OTHER 

OPERATIONS ON THE MACHINE. DO NOT ALLOW UNAUTHORIZED PERSONNEL TO USE THE 

MACHINE.

2 - APPLICATIONS

 

GB

Cop

yright ©2017 Idr

obase Gr

oup

. All rights r

eserv

ed.

Содержание AURORA

Страница 1: ...cchina e deve obbligatoriamente essere conservato per futuri riferimenti fino alla demolizione della macchina IMPORTANT Before installing and using the machine im perative that the in staller and the...

Страница 2: ...e or durability of the machine and create the potential risk to the machine itself or the staff as well as make void the warranty The descriptions and illustrations contained in this publication are n...

Страница 3: ...31 5 2 TOWER PACK 31 5 3 BASE PACK 31 6 ASSEMBLY AND INSTALLATION 32 7 OPERATION AND USE 7 1 ELECTRICAL CONTROLS 35 7 2 RANGE APPLICATIONS 36 7 3 WORKING LIMITS 36 7 4 EATER CONNCTION TO THE MACHINE...

Страница 4: ...follow the safety regulations to the country of installation in addition to the rules dictated by common sense You should not use the machine if you note any defects or damages that could compro mise...

Страница 5: ...OUP SRL 2 2 MACHINE IDENTIFICATION The machine is distinguished by a manufacturer s plate 2 3 WARRANTY All of our equipments are subjected to accurate and rigorous tests and are covered under warranty...

Страница 6: ...OT LIABLE The manufacturer is not liable for damage caused by the following Improper use of the machine or use by untrained people Use of non genuine spare parts Non compliance with maintenance Unauth...

Страница 7: ...both installation and storage During the handling of the machine on sloping surfaces potholes or on particularly un stable ground there is a risk that the machine chutes The movement of the machine u...

Страница 8: ...HED ON ALWAYS DISCONNECT FROM THE ELECTRICAL SUPPLY BEFORE CARRYING OUT REPAIRS OR REMOVING THE COVER WARNING AVOID STORING OR USING THE MACHINE IN EXTREME TEMPERATURES FROST MAY CAUSE SERIOUS DAMAGE...

Страница 9: ...o Gazebo Through the use of suitable optional kits or models for each of these types achieves maximum performance 3 2 COMPOSITION The main components of the machine are 3 PRODUCT PRESENTATION GB 4 12...

Страница 10: ...r 6 Max Load Table Top 5 kg 11 lb Frequency 50 Hz Water Tank 10 L 2 64 US gal Absorption 0 8 A Max Pressure 25 bar 362 6 psi Noisiness 51 Db Power 120 W 0 16 HP Flow rate 18 L h 0 079 USGpm INFORMATIO...

Страница 11: ...ng all of the requested accessories 5 2 TOWER PACK Rattan tower with fan electric and hydraulic connection Table N 2 semitables with centering pins Kit of screws for fan cover assembly Kit of screws f...

Страница 12: ...LATION GB AFTER UNPACKED PROCEDE WITH 1 OPEN THE DOOR OF THE RATTAN BASE GET OUT TANK AND CONNECT WATER PIPE ELECTRIC CABLE REPLACE TANK AND CLOSE THE DOOR OF THE RATTAN BASE Copyright 2017 Idrobase G...

Страница 13: ...THE WATER CONNECTIONS TUBE WHITE AND ELECTRICAL BLACK CORD H2O 4 FIX THE TOWER TO THE BASE TIGHTENING THE HEX SOCKET BUTTON HEAD CAP SCREWS M6X35 2 FIX FAN COVER AND FAN COVER SUPPORT TO THE FAN WITH...

Страница 14: ...TO THE RATTAN TOWER 8 FIX SEMI TABLES TIGHTENING THE HEX SOCKET BUTTON HEAD CAP SCREWS M6X15 9 SCREW IN NOZZLES THE INSTALLER MUST SECURELY TO THE FLOOR GROUND THE MACHINE WITH AT LEAST 3 SCREWS OF T...

Страница 15: ...y the LED continuous light shutdown is signaled by LED flashing light BLOCK PUMP If during operation of the pump there is no pressure in the line tank empty or broken hydraulic hose the pump stops Thi...

Страница 16: ...till closed dimensioned accor ding to the flow and pressure to which the system should work The pipes laid shall not have any bending Serial connection to the water supply is carried out by a female f...

Страница 17: ...DESTRUCTION OF THE MACHINE MUST BE CARRIED OUT ONLY BY A TRAINED PERSON OR BY A QUALIFIED TECHNICIAN When it has been decided to destroy the machine and render it unusable it is recom mended that all...

Страница 18: ...every 50 hours the proper functioning of the nozzles of the crown group that could get clogged due to the formation of limestone or using unclean water A nozzle is clogged note because drips or has a...

Страница 19: ...IT IS GOOD TO REMEMBER THAT THE MAINTENANCE CARRIED OUT PROPERLY CAN MINIMI ZE THE DOWNTIME DUE TO FAILURE A REPAIR DONE IN A TIMELY MANNER TO AVOID FURTHER DETERIORATION USE AS MUCH AS POSSIBLE ORIGI...

Страница 20: ...that all parts which could be dangerous are rendered safe removing all of the electrical components while conforming to current legislation regarding the scrapping of these materials The various comp...

Страница 21: ...43 11 ELECTRICAL DIAGRAM GB Copyright 2017 Idrobase Group All rights reserved...

Страница 22: ...Faulty fan Connect the plug to the power outlet Call Service The machine vibrates a lot and or is noisy Water level in the tank insufficient Faulty pump Fill the tank with drinking water Call Service...

Страница 23: ...45 NOTE GB Copyright 2017 Idrobase Group All rights reserved...

Страница 24: ...46 NOTE GB Copyright 2017 Idrobase Group All rights reserved...

Страница 25: ...47 NOTE GB Copyright 2017 Idrobase Group All rights reserved...

Страница 26: ...montaggio messa in funzione manutenzione preventiva installation start up preventive maintenance www idrobase com www idrotech com www sparesclub com www enjoyyourfurniture com Copyright 2017 Idrobase...

Отзывы: