background image

27

2 - APPLICATIONS 

2.1  

GENERAL WARNINGS

BEFORE INSTALLING AND USING THE MACHINE IT IS COMPULSORY THAT THE INSTALLER 

AND THE USERS READ AND UNDERSTAND ALL OF THE INFORMATION IN THIS MANUAL.

THIS MANUAL IS AN INTEGRAL PART OF THE MACHINE; IT MUST ALWAYS BE AVAILABLE 

DURING THE NORMAL OPERATION OF THE MACHINE AND IT IS IMPERATIVE THAT IT IS RE-

TAINED FOR FUTURE REFERENCE UNTIL THE DISPOSAL OF THE MACHINE.

THE COPYRIGHT OF THIS MANUAL “INSTRUCTION FOR INSTALLATION AND USE” IS THE 

PROPERTY OF 

IDROBASE GROUP SRL

. ALL OF THE INFORMATION (TEXT, DRAWINGS, DIA-

GRAMS, ETC.) CONTAINED IN THIS MANUAL IS CONFIDENTIAL. NO PART OF THIS MANUAL 

CAN BE REPRODUCED AND DISTRIBUTED (EITHER IN PART OR COMPLETE) BY ANY MEANS 

OF REPRODUCTION, (PHOTOCOPIES, MICROFILM, OR OTHER) WITHOUT WRITTEN AUTHORI-

ZATION FROM 

IDROBASE GROUP SRL

.

2.2  

MACHINE IDENTIFICATION

The machine is distinguished by a manufacturer’s plate

2.3  

WARRANTY

All of our equipments are subjected to accurate and rigorous tests and are covered under 

warranty in accordance with statutory law from manufacturing defects.

THE WARRANTY IS INVALIDATED IF THE USE OF THE MACHINE DOES NOT CONFORM TO 

THE INSTRUCTIONS FOR USE CONTAINED IN THIS MANUAL, AND IF THE ORIGINAL COMPO-

NENTS, ACCESSORIES, SPARE PARTS AND CONTROL SYSTEMS ARE NOT USED.

The warranty starts from the date of purchase within the meaning of the act concerning 

warranty in the country of sale. 

GB

IDROBASE GROUP S.r.l.

Via dell’Industria, 25

35010  BORGORICCO (PD) - ITALY

Tel. +39 049 9335903 r.a.   Fax +39 049 9335922

Modello

Model

Matricola

Production nr.

Anno

Year

Volt

Hz

Watt

Ampere

Pressione nominale

Nominal pressure

MODEL

VOLTAGE

DATE OF PRODUCTION

FREQUENCY

POWER ABSORBED

NOMINAL 

PRESSURE

CURRENT

ABSORBED

MANUFACTURER

NAME

PRODUCTION 

NUMBER

Cop

yright ©2017 Idr

obase Gr

oup

. All rights r

eserv

ed.

Содержание AURORA

Страница 1: ...cchina e deve obbligatoriamente essere conservato per futuri riferimenti fino alla demolizione della macchina IMPORTANT Before installing and using the machine im perative that the in staller and the...

Страница 2: ...e or durability of the machine and create the potential risk to the machine itself or the staff as well as make void the warranty The descriptions and illustrations contained in this publication are n...

Страница 3: ...31 5 2 TOWER PACK 31 5 3 BASE PACK 31 6 ASSEMBLY AND INSTALLATION 32 7 OPERATION AND USE 7 1 ELECTRICAL CONTROLS 35 7 2 RANGE APPLICATIONS 36 7 3 WORKING LIMITS 36 7 4 EATER CONNCTION TO THE MACHINE...

Страница 4: ...follow the safety regulations to the country of installation in addition to the rules dictated by common sense You should not use the machine if you note any defects or damages that could compro mise...

Страница 5: ...OUP SRL 2 2 MACHINE IDENTIFICATION The machine is distinguished by a manufacturer s plate 2 3 WARRANTY All of our equipments are subjected to accurate and rigorous tests and are covered under warranty...

Страница 6: ...OT LIABLE The manufacturer is not liable for damage caused by the following Improper use of the machine or use by untrained people Use of non genuine spare parts Non compliance with maintenance Unauth...

Страница 7: ...both installation and storage During the handling of the machine on sloping surfaces potholes or on particularly un stable ground there is a risk that the machine chutes The movement of the machine u...

Страница 8: ...HED ON ALWAYS DISCONNECT FROM THE ELECTRICAL SUPPLY BEFORE CARRYING OUT REPAIRS OR REMOVING THE COVER WARNING AVOID STORING OR USING THE MACHINE IN EXTREME TEMPERATURES FROST MAY CAUSE SERIOUS DAMAGE...

Страница 9: ...o Gazebo Through the use of suitable optional kits or models for each of these types achieves maximum performance 3 2 COMPOSITION The main components of the machine are 3 PRODUCT PRESENTATION GB 4 12...

Страница 10: ...r 6 Max Load Table Top 5 kg 11 lb Frequency 50 Hz Water Tank 10 L 2 64 US gal Absorption 0 8 A Max Pressure 25 bar 362 6 psi Noisiness 51 Db Power 120 W 0 16 HP Flow rate 18 L h 0 079 USGpm INFORMATIO...

Страница 11: ...ng all of the requested accessories 5 2 TOWER PACK Rattan tower with fan electric and hydraulic connection Table N 2 semitables with centering pins Kit of screws for fan cover assembly Kit of screws f...

Страница 12: ...LATION GB AFTER UNPACKED PROCEDE WITH 1 OPEN THE DOOR OF THE RATTAN BASE GET OUT TANK AND CONNECT WATER PIPE ELECTRIC CABLE REPLACE TANK AND CLOSE THE DOOR OF THE RATTAN BASE Copyright 2017 Idrobase G...

Страница 13: ...THE WATER CONNECTIONS TUBE WHITE AND ELECTRICAL BLACK CORD H2O 4 FIX THE TOWER TO THE BASE TIGHTENING THE HEX SOCKET BUTTON HEAD CAP SCREWS M6X35 2 FIX FAN COVER AND FAN COVER SUPPORT TO THE FAN WITH...

Страница 14: ...TO THE RATTAN TOWER 8 FIX SEMI TABLES TIGHTENING THE HEX SOCKET BUTTON HEAD CAP SCREWS M6X15 9 SCREW IN NOZZLES THE INSTALLER MUST SECURELY TO THE FLOOR GROUND THE MACHINE WITH AT LEAST 3 SCREWS OF T...

Страница 15: ...y the LED continuous light shutdown is signaled by LED flashing light BLOCK PUMP If during operation of the pump there is no pressure in the line tank empty or broken hydraulic hose the pump stops Thi...

Страница 16: ...till closed dimensioned accor ding to the flow and pressure to which the system should work The pipes laid shall not have any bending Serial connection to the water supply is carried out by a female f...

Страница 17: ...DESTRUCTION OF THE MACHINE MUST BE CARRIED OUT ONLY BY A TRAINED PERSON OR BY A QUALIFIED TECHNICIAN When it has been decided to destroy the machine and render it unusable it is recom mended that all...

Страница 18: ...every 50 hours the proper functioning of the nozzles of the crown group that could get clogged due to the formation of limestone or using unclean water A nozzle is clogged note because drips or has a...

Страница 19: ...IT IS GOOD TO REMEMBER THAT THE MAINTENANCE CARRIED OUT PROPERLY CAN MINIMI ZE THE DOWNTIME DUE TO FAILURE A REPAIR DONE IN A TIMELY MANNER TO AVOID FURTHER DETERIORATION USE AS MUCH AS POSSIBLE ORIGI...

Страница 20: ...that all parts which could be dangerous are rendered safe removing all of the electrical components while conforming to current legislation regarding the scrapping of these materials The various comp...

Страница 21: ...43 11 ELECTRICAL DIAGRAM GB Copyright 2017 Idrobase Group All rights reserved...

Страница 22: ...Faulty fan Connect the plug to the power outlet Call Service The machine vibrates a lot and or is noisy Water level in the tank insufficient Faulty pump Fill the tank with drinking water Call Service...