Interior installation
In
te
rio
r ins
tall
a
tio
n
5.9. Installation – Standard air duct
If there are no two external walls directly available for
installation, the air fl ow can be conveyed outwards
via insulated air ducts. Our range includes standard
air ducts which can be connected directly to the heat
pump without adaptation.
There are two ways to do this:
Option 1
Option 2
This method is used if there are no two external walls
available. As a short circuit may occur between the
supply and exhaust sides with this method, the inlet
and outlet should be positioned as far apart as pos-
sible. The unit can be separated from any shrubbery
by fi tting dividing walls if necessary.
This method is equivalent to corner installation. This
method can be used if corner installation is not pos-
sible due to space restrictions or if a gap needs to be
bridged between the heat pump and outlet side.
Air ducts can be connected to the right
and left of the heat pump. Heating and
electrical connections can also be fi tted
on both sides.