![IDK MSD-702UHD Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/idk/msd-702uhd/msd-702uhd_user-manual_3786615063.webp)
MSD-701UHD / 702UHD / 801UHD/ 802UHD User’s Guide
63
9.7.1 Automatic measurement
Menu Top
→
INPUT TIMING
→
AUTO SETUP
Setting for Each input channel, each input signal (only analog input signal)
Setting value
・
NORMAL MODE [Default]
・
4:3
・
5:3
・
16:10
・
NEXT ASPECT
・
5:4
・
16:9
Analog RGB/analog YPbPr input video is measured to set ”
9.7.2 The total number of horizontal
“ automatically.
Input video
Valid display
area
Input video
Input video
●Cannot be measured:
- Right and left sides of input video do not touch the circumscribed
rectangle.
- Brightness of input video is 24% or less.
●Can be measured:
- Input video contacts the circumscribed rectangle.
- Brightness of input video is 25% or more.
[Fig. 9.12] Conditions of automatic measurement
By selecting “NORMAL MODE”, the MSD performs automatic measurement of the start position and active
area. If edges of video are not displayed correctly, use this mode to set the start position and active area
automatically.
If the input video is not recognized correctly
like above, it can adjust by executing
“
NORMAL MODE
”
automatic input
measurement.
If the setting of active area is not correct
and it cannot adjust only by starting
position, the active area is also adjusted by
executing automatic input measurement.
[Fig. 9.13] Automatic measurement by “NORMAL MODE”