MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
86
@GEC / @SEC
Control command (contact closure)
Getting
Command
@GEC, no
Response
@GEC, no, delay, port, memo, ccno_1, cc_1, pulse_1 (, ccno_2, cc_2,
pulse_2
・・・
)
Setting
Command
@SEC, no, delay, port, memo, ccno_1, cc_1, pulse_1 (, ccno_2, cc_2,
pulse_2
・・・
)
Response
@SEC, no, delay, port, memo, ccno_1, cc_1, pulse_1 (, ccno_2, cc_2,
pulse_2
・・・
)
Parameter
no : Control command number
1 to 32
delay : Delay time
0 = 0 sec. to 999999 = 999.999 sec.
port : Contact closure control
8192= For contact closure control
memo:
Up to 14 characters of 20 to 7D except 2C (,) from ASCII codes.
ccno_1-3: Contact closure number
ccno
1
2
3
Contact
closure
CONTACT CLOSURE
CH1
CH2
CH3
cc_1-3: Contact closure control
0 = OFF, 1 = ON, 2 = Toggle, 3 = Not control
pulse_1-3: pulse width
0 = Hold, 100 = 100 ms to 9990 = 9990 ms (by 10 ms)
Pulse width after the completion of contact closure.
Getting commands: only contact closure numbers to be controlled are replied.
Setting commands: specify only contact closure numbers to be controlled. For
contact closure numbers that do not specify parameter, “Not check” is set.
Getting
example
Command
Response
@GEC,7
@GEC,7,20,8192,SCREEN UP,1,1,100
Description Getting settings of control command 7.
・
Delay time: 20ms
・
Memo: SCREEN UP
・
Contact closure1’s CH1: ON for 100 ms
・
Other outputs: not controlled.
Setting
example
Command
Response
@SEC,6,50,8192,PROJECTOR ON,1,0,200,2,1,0
@SEC,6,50,8192,PROJECTOR ON,1,0,200,2,1,0
Description Setting Control command number 6 as follows:
・
Delay time: 50 ms
・
Memo: PROJECTOR ON
・
CH1 of contact closure : ON for 200 ms
・
CH2 of contact closure : ON
・
CH3 of contact closure : not controlled
Remarks
-