MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
42
@GHT / @SHT
The total number of horizontal dots
Getting
Command
@GHT
Response
@GHT, h_total_1, h_total_2, h_total_3, h_total_4, h_total_5, h_total_6, h_total_7,
h_total_8
Setting
Command
@SHT, ch, h_total
Response
@SHT, ch, h_total
Parameter
h_total_1-8/ h_total: The total number of horizontal dots
400 to 4125 (sampling block should be 13 MHz to 162 MHz)
[Default] depends on input signal
ch: Input channel
0 =All analog inputs, 6 = IN6, 7 = IN7
Getting
example
Command
Response
@GHT
@GHT,2200,2200,0,2640,1344,1792,0,0
Description Getting the total number of horizontal dots.
IN1 and IN2: 2200 dots, IN4: 2640 dots, IN5: 1344 dots, IN6: 1792 dots.
“0” is returned to channels without input signal.
Setting
example
Command
Response
@SHT,7,1344
@SHT,7,1344
Description Setting the total number of IN7 horizontal dots to “1344”.
Setting
example
Command
Response
@SHT,7,1344
@ERR,3
Description If analog RGB signal or analog YPbPr signal is not input, an error is returned.
Remarks
Getting command acquires all channels’ statuses.
Setting commands are valid only if analog RGB/analog YPbPr signal is input.