MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
84
@GEC / @SEC
Control command (Displaying received data)
Getting
Command
@GEC, no
Response
@GEC, no, delay, port, memo, length, command, timeout, retry, interval,
retryover, display, delimiter
Setting
Command
@SEC, no, delay, port, memo, length, command, timeout, retry, interval,
retryover, display, delimiter
Response
@SEC, no, delay, port, memo, length, command, timeout, retry, interval,
retryover, display, delimiter
Parameter
no: Control command number
1 to 32
delay: Delay time
0 = 0 sec. to 999999 = 999.999 sec.
port: Output port
1 to 8191
bit
7
6
5
4
3
2
1
0
port
LAN
4
LAN
3
LAN
2
LAN
1
RS-232C
IN8
RS-232C
OUT2B
RS-232C
OUT1B
RS-232C
CH1
bit
15
14
13
12
11
10
9
8
port
-
-
-
LOOP
BACK
LAN
8
LAN
7
LAN
6
LAN
5
“1” is for the output port to send a command (Since bit 11-15 are not used, they
are always “0”). For example, if you want to send a command to RS-232C,
specify “1”. If sending a command to LAN 2, specify “32”.
memo:
Up to 14 characters of 20 to 7D except 2C (,) from ASCII codes.
length: Command data size (the number of bites)
0 to 30
command: Command data
Specify length × 2 digits with 0 to 9, A to F, a to f = 4 bit per digit (in
hexadecimal).
timeout: Time-out duration
0 = 0 sec. to 99999 = 99.999 sec.
retry: The number of retires
0 to 99
interval: Retry interval
0 = 0 sec. to 99999 = 99.999 sec.
retryover: Processing at retry over
0 = Stop processing, 1 = Continue processing
display : Displaying received data
1 = in ASCII codes, 2 = in hexadecimals
delimiter:
2 digits of 0 to 9, A to F, a to f = 4 bit per digit (in hexadecimal) for monitoring
delimiter
100 = Not monitor