MSD-501/502 Command Guide
85
@GCA / @ECA
Editing cross point memory (Setting audio channel)
Function
Getting
Setting
Format
@GCA, memory
@ECA, memory, a_1 (, a_2)
Return value
@GCA, memory, a_1 (, a_2) , name
@ECA, memory, a_1 (, a_2)
Parameter
memory: Cross point memory
1 to 7
a_1-2: Audio channel
-1 = Not controlled [Default], 0 = OFF, 1 = IN1 to 5 = IN5
name: Memory name
Up to 10 characters using 20 to 7D from ASCII codes. [Default] 20 (space)
Example
@GCA,2
@GCA,2,3,1,PATTERN2
Getting audio channel of cross point memory 2.
OUT1: IN3; OUT2: IN1 with the name of
“PATTERN2”
@ECA,2,1,2
@ECA,2,1,2
When cross point memory 2 is loaded, OUT1 is
set to IN1 and OUT2 is set to IN2.
Remarks
Nothing is saved in the memory by factory default, the state is “-1” (Not controlled). If
you save only video (@SCV) at the first saving of cross point settings, “-1” (Not
controlled) is replied to unsaved audio and video.
@RPM / @SPM
Saving all settings
Function
Setting
Saving
Format
@RPM, preset
@SPM, preset (, name)
Return value
@RPM, preset
@SPM, preset (, name)
Parameter
preset: Preset memory
1 to 8
name: Memory name
Up to 10 characters using 20 to 7D from ASCII codes.
If you do not specify memory name, only cross point settings are saved without
changing the memory name.
Example
@RPM,3
@RPM,3
Loading preset memory 3.
Completed normally.
@SPM,2
@SPM,2
Saving the current settings in preset memory 2
without changing the memory name.
@SPM,2,MEMORY2
@SPM,2,MEMORY2
Saving the current settings in preset memory 2
with the name of “MEMORY2”.
Remarks
Once preset memory is loaded, all settings of video and audio I/O except for some