![IDK MSD-501 Скачать руководство пользователя страница 79](http://html2.mh-extra.com/html/idk/msd-501/msd-501_command-reference-manual_3737534079.webp)
MSD-501/502 Command Guide
79
@GIT / @SIT
Ineffective time during control command execution
Function
Getting
Setting
Format
@GIT
@SIT, time
Return value
@GIT, time
@SIT, time
Parameter
time: Invalid time
0 = 0 second to 999999 = 999.999 seconds [Default] 0
Example
@GIT
@GIT,2000
Getting ineffective time of control command execution.
Disabling operation during control command execution
or 2000 ms. (2 seconds) after control command starts.
@SIT,2000
@SIT,2000
Setting ineffective time during control command
execution to 2000 ms. (2 seconds).
Completed normally.
Remarks
-
@DEC
Initializing registered command and association
Function
Setting
Format
@DEC, no_1 (, no_2, no_3
・・・
)
Return value
@DEC, no_1 (, no_2, no_3
・・・
)
Parameter
no_1-32: Commands or links to be initialized
1 to 32: control command 1 to 32
101 to 132: reply command 1 to 32 (“1xx”: xx is the reply command number)
201 to 237: control command link 1 to 37 (“2xx”: xx is the control command
execution condition)
【
@GRC / @SRC Reply command (P.77)
】
【
】
Example
@DEC,201
@DEC,201
Initializing POWER ON link
.
Completed normally.
Remarks
-