MSD-501/502 Command Guide
57
@GSF / @SSF
Sampling frequency
Function
Getting
Setting
Format
@GSF
@SSF, ch_1, frequency_1 (, ch_2,
frequency_2)
Return value
@GSF, frequency_1 (, frequency_2)
@SSF, ch_1, frequency_1 (, ch_2,
frequency_2)
Parameter
frequency_1-2: Sampling frequency
0 = AUTO-A [Default],
1 = AUTO-B,
2 = 32 kHz,
3 = 44.1 kHz,
4 = 48 kHz,
5 = 88.2 kHz,
6 = 96 kHz,
7 = 192 kHz
ch_1-2: Output channel
0 = All outputs, 1 = OUT1, 2 = OUT2
Example
@GSF
@GSF,0,2
Getting sampling frequency settings.
OUT1: AUTO-A; OUT2: 32 kHz
@SSF,1,3
@SSF,1,3
Setting OUT1 sampling frequency to 44.1 kHz.
Completed normally.
Remarks
-
@GFD
Actual sampling frequency
Function
Getting
Format
@GFD
Return value
@GFD, frequency_1 (, frequency_2)
Parameter
frequency_1-2: Sampling frequency
1 = 32 kHz,
2 = 44.1 kHz,
3 = 48 kHz [Default],
4 = 88.2 kHz,
5 = 96 kHz,
6 = 192 kHz
Example
@GFD
@GFD,5,3
Getting actual sampling frequency.
OUT1: 96 kHz; OUT2: 48 kHz
Remarks
If “
@GSF / @SSF Sampling frequency (P.57)
” is set to “AUTO-A” or “AUTO-B”, the
sampling frequency that is output actually will be replied. If it is set to value other than
“AUTO-A” or “AUTO-B”, the set sampling frequency will be replied.