MSD-402 User’s Guide
89
8.12.6 Copying output setting
Menu PRESET MEMORY
→
COPY OUTPUT MEMORY
Setting value OUT1
→
OUT2, OUT2
→
OUT1
You can copy output setting from one output to another output. PinP output settings are also copied at the
same time.
Click the “COPY” button to open the dialog box and click the “OK” button to copy the output settings.
[Table 8.20] Settings can be copied
Menu
Item
Switching input channel, PinP output
Output resolution, Aspect ratio for sink device, Output Display position
Output Display, Output Masking, Background color, Test pattern
Output Brightness, Output Contrast, Gamma
Output mode, Synchronous signal output with no input video,
Output video with no input video, Window transition effect,
HDCP output, The number of HDCP retries, Deep Color,
Output level, Output mute, Audio output connector,
Multi channel audio output, Test tone
Outputting bitmap image, Background color, Aspect ratio, Display position
Input channel assignment, Bitmap output at startup
Note:
CEC connection is only for one by one connection.
If the same video is set to connected to multiple outputs, the lowest output number will be connected
preferentially and other outputs cannot be connected.