HDC-TH401/201/101 User Guide
45
7.17 Setting EDID physical address copy
This setting is applied if the source and sink devices are connected and “
” is set
to a number of “3” to “22 (Built-in EDID)”.
EDID physical address of the monitor that is connected to the OUTPUT connector (selected
in “
”) is copied and then it is copied to the INPUT EDID.
If the CEC physical address of the connected sink device and the HDC’s address are not the same, the CEC
functions, such as input switching in the sink device at start-up, may not work correctly. The problem can be
solved by using the CEC physical address that is copied into the HDC.
・
Setting by menu
Normal condition (OFF)
↓ SET button
“
-
” “
+
” button
set INPUT EDID physical address copying → select F38
↓ SET button
“
-
” “
+
” button set Copy physical address [Default: OFF]
OFF : EDID physical address copy OFF
ON : EDID physical address copy ON
↓
During EDID physical address copying is processing, READY LED is OFF. After setting is
finished, the LED is ON
↓
After processing, 7-SEGMENT LED goes back to menu.