HDC-TH401/201/101 User Guide
25
7.3 Copying EDID
Tip:
“[ ]” shows each menu number in this chapter.
EDID of sink devices can be read and stored.
Use this feature in order to copy the EDID of another sink device. You can also use this feature in case the
EDID of the connected sink device cannot be used.
If EDID is already saved, the data will be overwritten.
To use the copied EDID:
Select the copied EDID in “
” and set the copy data number
in “
Up to three EDID can be stored.
To register EDID:
1. Save the sink device EDID to a copied data (1 to 3): Menu number [F01 to F03]
2. Select the copy data you want to use: Menu number [F14]
3. Select the Copy EDID: Menu number [F10]
[Fig. 7.2] Copying EDID
Menu numbers
F01 to F03: Copied data 1 to 3
Setting values
01 to 02: HDC OUT to OUT1 (HDC-RH101) [Default] 01: HDC OUT
01 to 03: HDC OUT to OUT2 (HDC-RH201) [Default] 01: HDC OUT
01 to 05: HDC OUT to OUT4 (HDC-RH401) [Default] 01: HDC OUT
Notes:
For cascade connection, the source device will read the EDID of the HDC that is connected to the source
device. If two or more distributors are connected between a sink device and source device, follow the
procedure below to read EDID data.
1. Copy the EDID of the sink device into the sink-device-side HDC-RHx01 unit and set its EDID as “Copied
EDID” or “EXTERNAL (External EDID)”.
2. Copy the EDID of the sink-device-side HDC-RHx01 into the HDC-Sx00 and set its EDID as “Copied EDID”
or “EXTERNAL (External EDID)”.
3. Copy the EDID of the HDC-Sx00 into the source-device-side HDC-THx01 and set its EDID as “Copied
EDID” or “EXTERNAL (External EDID)”.
HDC-TH401/201/101
TX
HDC-RH401/201/101
Projector
RX
Laptop
HDC-S400/200
Splitter
[Fig. 7.3] Reading EDID in cascade connection
to
OUT 1
OUT 4
LC monitor
Copied data 1
Copied data 2
Copied data 3
Copied EDID
EXTERNAL EDID
Internal EDID
Blu-ray disc player
Step 1
Step 2
Step 3