FDX-16 Command Guide
46
z
Switching I/O channel
Function
Getting
Setting
Format
z,output_xx
input_1,output_1 (,input_2,output_2
・・・
)
Return value
input_v/input_a
-
Parameter
input_1 to input_16 : Input channel
q = OFF, 0 = OFF, 1 to 16 = INPUT1 to INPUT16
output_1 to output_16 :output channel
r = All outputs (available only at the time of setting)
0 = All outputs (available only at the time of setting),
1 to 16 = OUTPUT1 to OUTPUT16
input_v : FDX input channel
input_a : MAU-1616 input channel
000 = OFF [Default], 001 to 016 = INPUT1 to INPUT16
Example
z,1
001/001
Getting the input channel that is set for
OUTPUT1.
OUTPUT1 of FDX and MAU-1616 is set to
INPUT1.
1,3
Setting OUTPUT3 to INPUT1.
Remarks
This mode is switched independently of the switching mode of the FDX front panel.
Switching mode that is set by conversion communication command will be used.
wva / w / wa
I/O channel status
Function
Getting
Format
wva
(Getting I/O channel statuses of FDX and MAU-1616)
w
(Getting I/O channel statuses of FDX)
wa
(Getting I/O channel statuses of MAU-1616)
Return value
v_1;
・・・
v_16/a_1;
・・・
a_16
(wva command return value)
v_1;
・・・
v_16
(w command return value)
a_1;
・・・
a_16
(wa command return value)
Parameter
v_1 to v_16 : FDX output channel
a_1 to a_16 : MAU-1616 output channel
000 = OFF [Default], 001 to 016 = INPUT1 to INPUT16
Example
wva
000;000;000;000;000;000;000;000;000;00
0;000;000;000;000;000;000/000;000;000;
000;000;000;000;000;000;000;000;000;00
0;000;000;000
Getting I/O channel statuses of FDX and
MAU-1616
All output channel: Input channel is set
to OFF
Remarks
-