FDX-16 Command Guide
24
2.5.3 Input setting
@GIQ / @SIQ
Input equalizer
Function
Getting
Setting
Format
@GIQ
@SIQ,in_1,level_1 (,in_2,level_2
・・・
)
Return value
@GIQ,level_1,
・・・
level_16
@SIQ,in_1,level_1 (,in_2,level_2
・・・
)
Parameter
in_1 to in_16 : Input channel
0 = All inputs, 1 to 16 = INPUT1 to INPUT16
level_1 to level_16 : Input equalizer of each input channel
0 = OFF, 1 = AUTO [Default], -1 = Digital input slot board is not mounted.
Example
@GIQ
@GIQ,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1
Getting input equalizer status.
All input channels: AUTO
@SIQ,0,0
@SIQ,0,0
Setting input equalizers of All input
channels to
“OFF”.
Completed normally.
Remarks
-
@GDT / @SDT
No-signal-input monitoring
Function
Getting
Setting
Format
@GDT
@SDT,in_1,time_1 (,in_2,time_2
・・・
)
Return value
@GDT,time_1,
・・・
time_16
@SDT,in_1,time_1 (,in_2,time_2
・・・
)
Parameter
in_1 to in_16 : Input channel
0 = All inputs, 1 to 16 = INPUT1 to INPUT16
time_1 to time_16 : Non-signal-input monitoring time of each input channel
0 = OFF, 3 to 15 = 3 to 15 seconds [Default]:10 seconds,
- 1 = Input slot board is not mounted.
Example
@GDT
@GDT,10,10,10,10,10,10,10,10,10,10,10,
10,10,10,10,10
Getting current settings of non-signal-input
monitoring time.
All input channels: 10 seconds
@SDT,0,4
@SDT,0,4
Setting non-signal-input monitoring time of
All input channel to 4 seconds.
Completed normally.
Remarks
-