FDX-16 Command Guide
30
@RME
Copying EDID
Function
Setting
Format
@RME,out,number
Return value
@RME,out,number
Parameter
out :Channel to be loaded
1 to 16 = OUTPUT1 to OUTPUT16
number : Destination memory number
1 to 4 = Memory 1 to 4
Example
@RME,1,1
@RME,1,1
Setting EDID of the sink device connected
to OUTPUT1 to Memory 1.
Completed normally.
Remarks
-
@GEC / @SEC
EDID loading channel
Function
Getting
Setting
Format
@GEC
@SEC,in_1,out_1 (,in_2,out_2
・・・
)
Return value
@GEC,out_1,
・・・
out_16
@SEC,in_1,out_1 (,in_2,out_2
・・・
)
Parameter
in_1 to in_16 : Input channel
0 = All inputs, 1 to 16 = INPUT1 to INPUT16
out_1 to out_16 : EDID loading channel of each input channel
1 to 16 = OUTPUT1 to OUTPUT16,
-1 = Input slot board is not mounted., -2 = Output slot board is not mounted.
Example
@GEC
@GEC,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1
Getting statuses of EDID loading channel.
All input channels: From OUTPUT1.
@SEC,0,1
@SEC,0,1
Setting EDID loading channels of all input
channels to OUTPUT1.
Completed normally.
Remarks
This command is available only if
“0” (External EDID) is selected for EDID resolution.