7

English

Video Display Area

Left-click on the video display area to toggle between split 
screen and single screen modes.

Drag the camera screens around to rearrange them.

Apply/Cancel Buttons

While in Camera Registration mode, select 

Apply

 to 

register all changes.

Select 

Cancel

 to exit Camera Registration mode without 

applying the changes.

•  A login is required when accessing Camera 

Registration mode for the first time. (Default ID is 
"admin". There is no password.)

•  It is not possible to register a camera that has 

already been registered to a different NVR.

Login

Configuring the NVR's settings and accessing its 
searching and other functions require an authorized user 
login.

Bring up the Live menu and either press the 

Setup

 

button on the remote control or click on 

 (Log in) 

using the mouse.

Select a user, enter the password, and then select 

OK

.

•  There is no default password for the admin 

account. Select "admin" and then "OK" 
without entering a password to log in.

•  Leaving the admin account unassigned with a 

password poses a security risk. Please assign 
a password at your earliest convenience. 
A warning message will continue to be 
displayed until a password is assigned.

•  Click on the 

 button next to the password 

field using the mouse. This will bring up a 
virtual keyboard you can use to assign a 
password.

To log out, bring up the Live menu and either press 
the 

Setup

 button on the remote control or click on 

 (Log out) using the mouse.

Basic Feature

 Live Mode

Once Camera Registration is complete, the system will 
enter Live Mode. 

Press the 

Setup

 button while in Live mode to bring up 

the Live menu on the top of the screen. Press 

Setup

 

once more to hide the menu. Use the Arrow buttons on 
the front panel of the NVR or the remote control to select 
the menu options.

Video Recording

Records the live video.

Refer to the Operation Manual for more information.

 Panic Recording

Select 

Live

 or 

Search

 menu's Panic Recording 

 icon 

or press the 

Panic Recording

 button on the front panel 

or the remote control to commence panic recording on all 
registered cameras.

To stop Panic Recording, select the Panic Recording 

 

icon or press the 

Panic Recording

 button again. If the 

Panic Recording Time

 option under 

Record Setup 

> General

 has been configured, Panic Recording will 

automatically terminate after the specified duration of time 
has elapsed.

•  Panic Recording takes place irrespective of any 

recording schedule set up by the user.

•  Panic Recording video profile from

 Record Setup – 

General

 applies to all Panic Recording videos.

Panic Recording will not take place if recording 
mode is not set to 

Recycle

 and the HDD has 

reached 100% of its capacity.

Audio Recording

If the Record Audio option under

 Camera Setup > 

Audio

 has been enabled for a specific camera, that 

camera will record audio along with video. 

Check your local laws and regulations on making 
audio recordings.

Video Recording Playback

You can play back video recordings by using mouse or 

remote control.

Содержание DR-6100 Series

Страница 1: ...IDIS Co Ltd For more information please visit at www idisglobal com Ver 1 00...

Страница 2: ...DR 6100 Series DR 4100 Series Network Video Recorder Quick Guide Powered by...

Страница 3: ...ied technician to restore the equipment to its normal operation E If the equipment has been dropped or the cabinet damaged F When the equipment exhibits a distinct change in performance this indicates...

Страница 4: ...Control Rack mount Kit Assembly Screws for Adding Hard Disk Drives SATA2 cables Overview Front Panel 9 9 1 2 3 4 5 6 7 8 0 1 Panic Recording Button 2 Alarm Button 3 PTZ Button 4 Layout Button 5 Searc...

Страница 5: ...Out Port 4 HDMI Out Port 5 eSATA Ports 6 Alarm Connection Ports 7 RS485 Port 8 RS232 Port 9 Network Port 0 Video In Ports Power In Port Vent For more details on rear panel connections refer to the ope...

Страница 6: ...d Bookmark Button e Clip Copy Button f Mute Button For more details on remote control buttons refer to the operation manual Getting Started Setup Wizard Starting up the system for the first time auto...

Страница 7: ...can for DirectIP cameras that were not scanned automatically If the auto scan option has been disabled the system will not automatically recognize new DirectIP camera connections In this case press th...

Страница 8: ...on on the remote control or click on Log out using the mouse Basic Feature Live Mode Once Camera Registration is complete the system will enter Live Mode Press the Setup button while in Live mode to b...

Страница 9: ...d click LOGIN to sign in using the selected mode If connecting by entering http web idisglobal com enter the NVR s IP address in the Device Address field Selecting the Use FEN option on the login wind...

Страница 10: ...rd set by default Leaving the admin account unassigned with a password poses a security risk Please assign a password at your earliest convenience Once the program is running you must login Enter a Us...

Страница 11: ...of the selected site will be displayed on the screen Recorded Video Playback 1 In the Site List make sure that the device has been added to the device group 2 In the panel tabs click on the Play tab I...

Страница 12: ...ith 6HDDs DR 6100 Series 7 6kg with 4HDDs DR 4100 Series Weight Packaging 12 0kg with 6HDDs DR 6100 Series 10 8kg with 4HDDs DR 4100 Series Packaging Dimensions W x H x D 540mm x 290mm x 590mm Working...

Отзывы: