background image

DC-SP6C11EXY

  Explosion-proof Fisheye camera

·

Instruction Manual

15 

Cautions in service: 

It’s not suggested for users to dismantle this product at will, please follow the Instruction
for operation.

The power must comply with requirements specified in 1.5.

Please use this product in conditions (atmosphere pressure, temperature and humidity)
specified in chapter 1.6.

Since Ex product is very special, debugging with power before installation if available.

No extra load on the camera, extra load may cause malfunction or damage!

After the inspection of the factory products are not allowed to change the part which has
impact on explosion-proof performance.

Internal and external grounding shall be reliable .The grounding wire resistance should
be less than 1

Ω

. The ground resistance should less than 1

Ω

.

2.2. Preparation of supports before installation 

Since Ex product is very special, We suggest that it is better to do debugging with power 
before installation if available. After you are familiar with Ex product’s operation, then do the 
site installation.

 

The debugging is done before package, only installation in the intended 

location is required. We strongly suggest you select supports from IDIS, it will ease your 
installation process significantly.

 

It’s the user’s responsibility to ensure the support for the camera is strong enough, and the 
fasteners comply with associate load and anti-rust requirements. Installation of the camera 
shall ensure that it’s out of reach by human beings and there is no other subject may affect the 
rotation of the camera; otherwise, falling or damage may happen, even personnel safety may 
be harmed. 

2.2.1 Support installation 

After open package, select installation holes in proper positions for wall/ceiling mount bracket. 
The first step is to ensure the direction of the camera is correct, and then fasten the wall 
bracket with M8×25 Outer hexagonal bolt.   
Junction box is always installed in positions that easy for installation and maintenance, as per 
Figure 2.2.1.1. The cable is connected to junction box by wire casings or bridges. 

Содержание DC-SP6C11EXY

Страница 1: ...Explosion proof IR Mini Fisheye camera Instruction Manual DC SP6C11EXY...

Страница 2: ...s product VIII Thank you for choosing IDIS Ex products Please read this Instruction Manual carefully before installation and operation of this product following the instructions and keep this instruct...

Страница 3: ...latest product information on our website http www idisglobal com Quality Guarantee For DC Explosion proof Fisheye Camera we provide free maintain service in the guarantee period but we will ask the...

Страница 4: ...al Ensure this product is always used in environment with atmosphere pressure ambient temperature and relative humidity specified in Chapter 1 6 To be sure the power supply complies with the requireme...

Страница 5: ...Instruction Manual otherwise fault may happen Protect the flame proof joint in maintenance avoid any metal fragment or other substances get access in the internal chamber No disassembly or modificati...

Страница 6: ...ll affect the duration of the CCD or CMOS Transport operate and store this product in applicable temperature and humidity range Do not locate it in wet overheated over 60 C extreme cold less than 40 C...

Страница 7: ...sed for camera cleaning they may damage the surface or even decrease the service performance This product shall be installed and repaired by authorized personnel please do not dismantle or repair it b...

Страница 8: ...he latest software and description document by consulting the customer service department Any problem in operation of this product please contact the distributor or customer service department 82 1599...

Страница 9: ...kage or deformation allowed after test The maximum surface temperature will no more than 80 C in normal operation Tempering glass is adopted in observation port the tempering glass shall pass the impa...

Страница 10: ...nergize the product holding the bottom part to move it no force on the sunshade wiper base no dragging or knocking allowed When the product is energized it s NOT allowed to open move knock or drag thi...

Страница 11: ...16 2 3 1 Instruction for installation of camera and wall mounting bracket 16 2 3 2 Instruction and explosion proof flexible conduit 17 2 3 3 Instruction and ceiling mounting bracket 16 2 3 4 Instruct...

Страница 12: ...of monitoring the hazardous area The camera is designed and manufactured according to EN IEC60079 0 2018 EN60079 1 2014 EN60079 31 2014 IEC60079 0 2017 IEC60079 1 2014 IEC60079 31 2013 The compact str...

Страница 13: ...ll light 1 2 Characters This camera integrated a variety of communication protocols and speed it plays an important role in security systems This camera can work at wide voltage range and its self ada...

Страница 14: ...tically below 10 C Weight net DC 3 6kg Weight gross DC 4 6kg Figure 1 4 1 Dimensions of DC Explosion proof Camera 1 5 Electrical parameters Voltage and current 24V a c or 24V d c or 12V d c or PoE 48V...

Страница 15: ...be made in compliance with the structural specifications provided by the manufacturer Repairs must not be made on the basis of values specified in tables 3 and 4 of EN IEC 60079 1 The fasteners which...

Страница 16: ...have no cracks and defects affecting explosion proof performance Cautions before installation Accessories in packaged product 1 DC main set 1pcs 2 Wall mounting bracket or ceiling mounting bracket 1p...

Страница 17: ...r before installation if available After you are familiar with Ex product s operation then do the site installation The debugging is done before package only installation in the intended location is r...

Страница 18: ...ll mounting bracket Figure 2 2 1 2 ceiling mounting bracket 2 3 On spot installation and fixing Since Ex product is very special adjust with power indoors before installation in the intended locations...

Страница 19: ...xible conduit Reference 2 3 2 1 for the bracket mounting camera and flexible conduit 1 Firstly the safety rope on the camera is hung on the safety hook of the installation bottom reference 2 3 2 1 and...

Страница 20: ...mera 4 fasten the M6 lifting bolt on the bottom mounting hole of camera Figure 2 3 3 1 camera and ceiling mount bracket 2 3 4 Instruction for installation of camera ceiling mounting bracket and explos...

Страница 21: ...1 System connection Network model device adopts cable network or wireless network as the main network for digital video signal transmission it s available for users to monitor or record the videos at...

Страница 22: ...ck Audio grounding white purple Audio input white blue Alarm input 1 Blue thin Alarm input 2 White brown Alarm input 3 brown thin Alarm input 4 White red Alarm input 5 red Alarm input 6 gray Alarm inp...

Страница 23: ...er and client software See camera manufacturer s instruction manual for camera IE browser and client software setting 3 Trouble shooting Phenomenon Analysis Solution No image No power supply Check the...

Страница 24: ...his product can be stored for one year in such environment no corrosive substance no obvious vibration temperature range 0 C 40 C and humidity no more than 90 4 3 Maintenance Six months after putting...

Страница 25: ...ar Field of View 180 H 180 V 180 D Video compression H 265 H 264 MP M JPEG Audio compression ADPCM 16K G 726 G 711 u Law G 711 a Law Primary bitstream resolution and FPS DirectIP Mode 3200x2944 800x73...

Страница 26: ...t of the poisonous harmful substances or elements in the component homogeneous material is lower than the limit specified in the standard 2 Symbol means the content of the poisonous harmful substances...

Страница 27: ...the following conditions the product is not considered within the quality guarantee scope Client cannot bring forth the quality guarantee card and invoice or receipt of purchasing Improper service con...

Страница 28: ...___________________ ________ S N ________________________ ______________ Date of manufacture __________ YYYY ________ MM ________ DD Date of purchase __________ YYYY ________ MM ________ DD If you hav...

Страница 29: ...Korea 4 Base Model DC Variant Model DC E5M180 DC E6M180 DC E12M180 DC SP6C11EXY DC SP6D11EXY 5 ATEX Directive 2014 34 EU 6 Ex marking 2 G Ex db op is C T6 Gb 2 D Ex tb op is C T80 Db with fill light...

Страница 30: ...28...

Отзывы: