Document Version 1.2
Last revised on
2017-09-26
Page 82 of 92
Reference Manual for uTrust 4701F and uTrust 4711F Readers
6.3.5.11.
CONTACT_GET_SET_ETU
This Escape command is used by the HOST to get/set the current ETU for smart cards. Once set, the
new ETU value will take effect immediately.
Input:
The input buffer contains the Escape code followed by an 8 bit GET/SET identifier. For SET ETU, a
DWORD specifying the value to be set is following.
Byte0
Byte1
Byte2
Byte3
Byte4
Byte5
Value
Description
Wait time
Escape
code(0x80)
0x01
SET ETU
BIT31-BIT24
BIT23-BIT16
BIT15-BIT8
BIT7-BIT0
0x00
GET ETU
-
-
-
-
Output:
For both Set and Get ETU, the output will be the following.
Byte0
Byte1
Byte2
Byte3
ETU value
BIT31-BIT24
BIT23-BIT16
BIT15-BIT8
BIT7-BIT0
DataIn =
80 00
DataOut:
00 00 01 40
(4 bytes)