6.3.2.
Escape command codes
Escape commands can be used by an application to configure uTrust 47xx F to function in a mode that
is not its default configured mode or to get specific information. To put the uTrust 47xx F back into its
default mode, it either has to be unplugged and plugged again or the application can send the same
Escape command again.
The following Escape commands are supported by uTrust 47xx F:
6.3.3.
Common for Contact and Contactless Interfaces
ESCAPE COMMAND
ESCAPE CODE
READER_SETMODE
0x01
READER_GETMODE
0x02
READER_GETIFDTYPE
0x12
READER_LED_CONTROL
0x19
READER_GETINFO_EXTENDED
0x1E
READER_LED_CONTROL_BY_FW
0xB2
READER_RDWR_USR_AREA
0xF0
READER_GENERIC_ESCAPE
FF 70 04 E6 XX