4.5 > Wiegand wiring
Wiegand input
21
Green / Red
WIEGAND_IN0
In
Wiegand IN D0
(Output type required: Open drain or
5V+/-5%)
23
White / Red
WIEGAND_IN1
In
Wiegand IN D1
(Output type required: Open drain or
5V+/-5%)
16
Yellow
GPO0
Out
Wiegand LEDIN (typical = 5VDC)
(option)
27
Black / Red
WIEGAND_GND
Ground for Wiegand
Figure 22: Wiegand input wiring
If pull-
up’s to 12V have been added on Wiegand IN D0 and Wiegand IN D1 inputs on a
previous installation with a MorphoAccess® 500 Series terminal, these resistors must be
removed to avoid any damage to the VisionPass terminal.
Содержание VisionPass
Страница 1: ...Copyright 2019 Idemia October 2019 2019_2000045728 VisionPass Installation guide...
Страница 2: ...Copyright 2019 Idemia October 2019 2019_2000045728...
Страница 7: ...7 VisionPass 2019_2000045728 1 Introduction...
Страница 20: ...20 VisionPass 2019_2000045728 2 General description...
Страница 28: ...28 VisionPass 2019_2000045728 3 Installation procedure...
Страница 37: ...37 VisionPass 2019_2000045728 3 3 4 Attach the device on the base plate 2x 2x...
Страница 42: ...42 VisionPass 2019_2000045728 4 Electrical interface...
Страница 58: ...58 VisionPass 2019_2000045728 5 User interface...
Страница 62: ...62 VisionPass 2019_2000045728 6 Accessories Software Licenses and PC Applications...
Страница 65: ...65 VisionPass 2019_2000045728 7 Recommendations...
Страница 68: ...68 VisionPass 2019_2000045728 8 Annex 1 placement recommendations...
Страница 71: ...71 VisionPass 2019_2000045728 9 Annex 2 Bibliography...
Страница 74: ...74 VisionPass 2019_2000045728 10 Annex 3 Support...
Страница 76: ...Copyright 2017 Photo GettyImages 656164914 Copyright 2017 Photo GettyImages 656164914...