Operating Instructions
IDEM Safety Switches
NET-BOX-CS
102638 2305 NET-BOX-CS Operating Instructions
5
Network Address
–
Setup/Initial Setting
The NET-BOX IP address can be set via DHCP server or statically via the device DIP switches.
The NET-BOX in its out-of-the-box state will have DHCP enabled (All DIP switches OFF, no IP address set).
Setting via DIP Switch
To manually assign a static IP the DIP switches located inside the NET-BOX are used. The following steps
can be performed with the device powered on or off, note the final step if the device is powered.
•
Remove the lid screws and turn over the NET-BOX Lid to locate the DIP switches (see below).
•
Using a small tool push the required switches to the ‘ON’ position to set the corresponding bit.
•
The address is given by adding the values of the DIP switches in the ON position.
•
Cycle power to the NET-BOX or press and hold the reset button until the LEDs turn red then release
to reset the device.
•
The NET-BOX will restart with the configured IP address and with DHCP disabled.
•
Replace the NET-BOX Lid and Lid screws, ensuring a tight seal of the lid.
INFORMATION
•
The example given in the image above shows only switches 2, 16 and 64 set to the
‘ON’ position.
The resulting IP address is: 192.168.1.
82