5

4.

 

INSTALLATION: _______________________________________________________________________________________________  

 
 
4.1.

 

Installation of the power supply 

 
Always install the POWER SUPPLY of the DOMOTIC Series system VERTICALLY on a solid and rigid surface (wall) as shown in the 

recommended installation diagram (Figs. 1,2). In order to guarantee a good state of conservation, the POWER SUPPLY should be installed 
in a well-ventilated dry place. Due to IP degree of the POWER SUPPLY the DOMOTIC Series system should not be installed outdoors. The 
POWER SUPPLY should be installed a bit distant from the electrolysis cell so that it cannot accidentally suffer water splashes. 

Beware of corrosive atmosphere formation due to pH decreasing solutions (specially, those ones based on hydrochloric acid "HCl"). Do not 
install the DOMOTIC Series system near to any stores of these chemicals. We strongly recommend the use of chemicals based on sodium 
bisulphate or diluted sulphuric acid. Power supply must be connected to the electrical control box of the pool, so that the pump and the 
DOMOTIC Series System are turned on (and off) simultaneously. 
 
 
4.2.

 

Installation of the electrolysis cell 

 

The electrolysis cell is made of a transparent polymer in whose interior the electrodes are placed. The electrolysis cell must be always 
installed indoors and after the pool filter, and after any other equipment that may be present (heat pumps, control systems, etc.).  

The installation of the cell should allow easy access to the installed electrodes by the user. It is highly recommended to install the electrolysis 
cell VERTICALLY, in a place of the pipe that can be easily isolated from the rest of the installation by two valves, so that the tasks of 
maintenance can be carried out with no need of partial or total draining of the swimming pool.  

Where the cell is installed on a by-pass (recommended option), a valve to regulate the flow must be introduced. Prior to installation, please 
consider the following commentaries: 

 

 

Fig. 3 

 

 

Fig. 4 

 

 

Fig. 5 

1. Flow direction marked in the cell 
must be respected. Recirculation 
system must guarantee the minimum 
flow stated in the Table of Technical 
Specifications for each model (see 
Section 9). 

2. The system flow detector activates if 
there is not recirculation (flow) of water 
through the cell or if flow is very low. If 
electrolysis gases are not properly 
removed through the electrolysis cell, 
the generated gas bubble electrically 

isolates the auxiliary electrode 
(electronic detection). Therefore, when 
locating the electrodes in the cell, the 
level sensor (auxiliary electrode) will 
have to be located in the higher area of 
the cell. The safest orientation is shown 
in the recommended installation 
diagram. 

3. WARNING: if the in-out valves of the 
electrolysis cell are closed 
simultaneously, the flow detector (gas 
detector) will not work correctly, with 
the consequent risk of cell breakdown. 
Although this situation is extremely 

unusual,  it can be easily avoided once 
the equipment has been installed, by 
locking at opened position the return 
valve to the swimming pool, so it 
cannot accidentally be manipulated. 

 

Содержание DOM-12 PH

Страница 1: ......

Страница 2: ...This salty water then passes through the electrolysis cell that is located in the plant room The DOMOTIC Series Salt Electrolysis System consists of two elements an electrolysis cell and a power supp...

Страница 3: ...potential free contact for external flow detector and ORP RESIDUAL CHLORINE control Programmable contact logics from unit control panel Salt level protection Automatic production protection ELECTROLY...

Страница 4: ...3 Fig 1 Recommended installation diagram DOMOTIC Series DOM XX...

Страница 5: ...4 Fig 2 Recommended installation diagram DOMOTIC Series DOM XX PH and DOM XX PLUS...

Страница 6: ...of the cell should allow easy access to the installed electrodes by the user It is highly recommended to install the electrolysis cell VERTICALLY in a place of the pipe that can be easily isolated fro...

Страница 7: ...en the electrolysis cell and the power supply according to the following scheme Due to relatively high current intensity circulating do not modify or cut either the length or section of the supplied c...

Страница 8: ...13 Fig 12 Fig 13 4 5 Installation of the optional external flow detector not included with the equipment 1 Install the saddle supplied in a section of the pipe at the entrance to the electrolysis cell...

Страница 9: ...Fig 11 1 and sliding upwards and outwards Fig 11 2 Then turn the cover to the left Fig 11 3 and disconnect the communications bus A from power and visualization cards Fig 11 4 2 Unscrewing its four f...

Страница 10: ...9...

Страница 11: ...10 4 8 Controls and indicators DOMOTIC Series electrolysis systems are equipped with a control panel in the front Figs 15 16 16b Fig 15 DOM XX models control panel Fig 16 DOMXX PH models control panel...

Страница 12: ...tors DIRECT REVERSE polarity 11 Display of SYSTEM INFORMATION 12 Indicator of FLOW ALARM 13 Indicator of ELECTRODE passivation ALARM 14 Key increase production programming menu navigation 15 Display o...

Страница 13: ...ent input for potential free contact When the contact connected to this input is open external flow detector at rest and the FS is configured as FS1c the electrolysis system switches off due to the fl...

Страница 14: ...the minimum recommended level of salt 5 g l should be maintained by adding 5 kg per m 3 of water if the water did not previously contain salt Always use common salt sodium chloride without additives l...

Страница 15: ...s you to establish the following operative parameters MODEL domotic 12 domotic 24 domotic 32 domotic 42 SOFTWARE VERSION Shows software version two digits POLARITY SWITCH Switch every 2 hours 2 Switch...

Страница 16: ...15 Fig 23 System programming flow sheet...

Страница 17: ...tion value 4 could be lower than the programmed and displayed value 11 WINTER Mode during periods of low water temperature select a production level 1 in the 50 60 range 5 4 Salinity test The DOMOTIC...

Страница 18: ...OF THE PH ORP SENSORS models DOM XX PH and DOM XX PLUS Connect the pH ORP sensor provided with the unit to the corresponding BNC connectors located in the unit s base Fig 26 5 5 2 CONNECTION OF THE D...

Страница 19: ...the dosage pump which allows to avoid the following situations Damages caused by the dry operation of pump depleted pH minus product Over dosage of pH minus product damaged or aged sensor PH regulati...

Страница 20: ...VEL If there is less than the recommended salt content in the pool the selected output level cannot be reached The LOW SALT 6 light will stay on In this case measure the salt level in the water and ad...

Страница 21: ...System running 2 Gas detected Insufficient flow System off Fig 29 OPTIONAL EXTERNAL FLOW DETECTOR FLOW SWITCH not included with the equipment During the system configuration process point 5 2 the inpu...

Страница 22: ...due to excessive scaling on the electrodes when the system operates with hard water with a high pH value Fig 31 PH ORP OUT OF RANGE only in models DOM XX PH and DOM XX PLUS The integrated pH ORP contr...

Страница 23: ...Although all DOMOTIC series salt electrolysis units are SELF CLEANING a prolonged operation of the system at pH values over 7 6 in waters of high hardness can produce scale formation on the surface of...

Страница 24: ...until the pH screen 15 displays a blinking 7 0 3 Gently shake the sensor to remove any possible drops of water and insert in the standard pH 7 0 solution green Gently shake for a few seconds and pres...

Страница 25: ...ntroller will be determined in each particular application Nevertheless we recommend to make it at least once a month during the use period of the pool The ORP controller has an automatic calibration...

Страница 26: ...lay 21 will indicate E2 not allowing calibration If the ORP measure is unstable during the calibration process code E3 will appear in display 21 In addition the sensor calibration will not be allowed...

Страница 27: ...zer cyanuric acid until a concentration of 25 30 g m 3 is achieved pH ORP controller always show extreme values or readings are unstable The cable of the pH ORP sensor is damaged Clean the contacts or...

Страница 28: ...pump Electrolysis display card Electrolysis pH display card Electrolysis PH ORP display card Power transformer 190 VA Power transformer 370 VA Power transformer 480 VA Power transformer 490 VA Extern...

Страница 29: ...42 8 m3 h Electrode number Domotic Series 12 5 Domotic Series 24 7 Domotic Series 32 7 Domotic Series 42 13 Net weight packaging included Domotic Series 12 11 Kg Domotic Series 24 13 Kg Domotic Series...

Страница 30: ...29 Dimensions DOMOTIC DOM XX models DOMOTIC PH PLUS DOM XX PH and DOM XX PLUS models...

Страница 31: ...ve the buyer must closely follow the manufacturer s instructions included in the documentation supplied with the product as applicable to each product range and model 10 2 2 Whenever a schedule is def...

Страница 32: ...cambiare totalemente o parzialmente le caratteristiche technique dei nostri prodotti ed il cotenuto di questo docuemntosenza nessum preavviso Wir behalten uns das recht vor die eigenschatten unserer p...

Отзывы: