WARRANTY CONDITIONS: ____________________________________________________________________________________   

 
 
10.1.

 

GENERAL ASPECTS 

 
10.1.1.

 

According to these provisions, the seller guarantees that the guaranteed product is in perfect condition upon delivery.  

10.1.2.

 

The Total Warranty period is 2 YEARS. 

10.1.3.

 

The Warranty period will be calculated as of delivery to the purchaser. The electrode is covered by a 2-YEAR WARRANTY (or 
5.000 hours), which is not extendable. The pH /ORP sensors are covered by a 6-MONTH non-renewable warranty. 

10.1.4.

 

Should the Product be faulty and the seller is notified during the Guarantee Period, he shall repair or replace the Product at his own 
cost wherever he sees fit, unless this is either impossible or out of proportion.  

10.1.5.

 

When the Product cannot be repaired or replaced, the buyer may request a proportional price reduction or, if the fault is important 
enough, rescission of the sales contract. 

10.1.6.

 

Parts replaced or repaired pursuant to this warranty shall not extend the warranty period of the original Product, although they shall 
have their own warranty. 

10.1.7.

 

For this warranty to be effective, the buyer shall accredit the date of acquisition and delivery of the Product.  

10.1.8.

 

When the buyer alleges a fault in the product over six months after its delivery, he shall accredit the original and existence of the 
alleged fault.  

10.1.9.

 

This Warranty Certificate does not limit or prejudge consumer rights pursuant to national legislation.  

 
 
10.2.

 

SPECIFIC CONDITIONS 

 
10.2.1.

 

For this warranty to be effective, the buyer must closely follow the manufacturer’s instructions included in the documentation 
supplied with the product, as applicable to each product range and model.  

10.2.2.

 

Whenever a schedule is defined for the replacement, maintenance or cleaning of certain product parts or components, the warranty 
shall only be valid when said schedule has been correctly followed. 

 
 
10.3.

 

LIMITATIONS 

 
10.3.1.

 

This warranty shall only be applicable to sales to consumers, with consumer being defined as a person who purchases the product 
for other than professional purposes. 

10.3.2.

 

No warranty is applicable to normal wear or the product, parts, components and/or fungible or consumable materials (except the 
electrode). 

10.3.3.

 

The warranty does not cover cases in which the product: (i) has been incorrectly treated; (ii) has been inspected, repaired, 
maintained or handled by an unauthorised person; (iii) has been repaired or maintained with non-original parts, or (iv) has been 
incorrectly installed or started up. 

10.3.4.

 

When a faulty product results from incorrect installation or start-up, this warranty shall only be applicable when the installation or 
start-up forms part of the product contract of sale and had been performed by the seller or under the seller’s responsibility. 

10.3.5.

 

Damage or faults due to any of the following causes: 

 

o

 

Bad programming of the system and/or user inadequate calibration of the pH/ORP sensors.

 

o

 

Operation at salinity values of less than 3 g of sodium chloride per litre and/or temperatures lower than 15

o

C (59

o

F) or higher 

than 40

o

C (104

o

F). 

o

 

Operation at a pH of more than 7.6. 

o

 

Use of explicitly unauthorised chemicals. 

o

 

Exposure to corrosive environments and/or temperatures of less than 0

o

C (32

o

F) or more than 50

o

C (125

o

F).  

 

Содержание DOM-12 PH

Страница 1: ......

Страница 2: ...This salty water then passes through the electrolysis cell that is located in the plant room The DOMOTIC Series Salt Electrolysis System consists of two elements an electrolysis cell and a power supp...

Страница 3: ...potential free contact for external flow detector and ORP RESIDUAL CHLORINE control Programmable contact logics from unit control panel Salt level protection Automatic production protection ELECTROLY...

Страница 4: ...3 Fig 1 Recommended installation diagram DOMOTIC Series DOM XX...

Страница 5: ...4 Fig 2 Recommended installation diagram DOMOTIC Series DOM XX PH and DOM XX PLUS...

Страница 6: ...of the cell should allow easy access to the installed electrodes by the user It is highly recommended to install the electrolysis cell VERTICALLY in a place of the pipe that can be easily isolated fro...

Страница 7: ...en the electrolysis cell and the power supply according to the following scheme Due to relatively high current intensity circulating do not modify or cut either the length or section of the supplied c...

Страница 8: ...13 Fig 12 Fig 13 4 5 Installation of the optional external flow detector not included with the equipment 1 Install the saddle supplied in a section of the pipe at the entrance to the electrolysis cell...

Страница 9: ...Fig 11 1 and sliding upwards and outwards Fig 11 2 Then turn the cover to the left Fig 11 3 and disconnect the communications bus A from power and visualization cards Fig 11 4 2 Unscrewing its four f...

Страница 10: ...9...

Страница 11: ...10 4 8 Controls and indicators DOMOTIC Series electrolysis systems are equipped with a control panel in the front Figs 15 16 16b Fig 15 DOM XX models control panel Fig 16 DOMXX PH models control panel...

Страница 12: ...tors DIRECT REVERSE polarity 11 Display of SYSTEM INFORMATION 12 Indicator of FLOW ALARM 13 Indicator of ELECTRODE passivation ALARM 14 Key increase production programming menu navigation 15 Display o...

Страница 13: ...ent input for potential free contact When the contact connected to this input is open external flow detector at rest and the FS is configured as FS1c the electrolysis system switches off due to the fl...

Страница 14: ...the minimum recommended level of salt 5 g l should be maintained by adding 5 kg per m 3 of water if the water did not previously contain salt Always use common salt sodium chloride without additives l...

Страница 15: ...s you to establish the following operative parameters MODEL domotic 12 domotic 24 domotic 32 domotic 42 SOFTWARE VERSION Shows software version two digits POLARITY SWITCH Switch every 2 hours 2 Switch...

Страница 16: ...15 Fig 23 System programming flow sheet...

Страница 17: ...tion value 4 could be lower than the programmed and displayed value 11 WINTER Mode during periods of low water temperature select a production level 1 in the 50 60 range 5 4 Salinity test The DOMOTIC...

Страница 18: ...OF THE PH ORP SENSORS models DOM XX PH and DOM XX PLUS Connect the pH ORP sensor provided with the unit to the corresponding BNC connectors located in the unit s base Fig 26 5 5 2 CONNECTION OF THE D...

Страница 19: ...the dosage pump which allows to avoid the following situations Damages caused by the dry operation of pump depleted pH minus product Over dosage of pH minus product damaged or aged sensor PH regulati...

Страница 20: ...VEL If there is less than the recommended salt content in the pool the selected output level cannot be reached The LOW SALT 6 light will stay on In this case measure the salt level in the water and ad...

Страница 21: ...System running 2 Gas detected Insufficient flow System off Fig 29 OPTIONAL EXTERNAL FLOW DETECTOR FLOW SWITCH not included with the equipment During the system configuration process point 5 2 the inpu...

Страница 22: ...due to excessive scaling on the electrodes when the system operates with hard water with a high pH value Fig 31 PH ORP OUT OF RANGE only in models DOM XX PH and DOM XX PLUS The integrated pH ORP contr...

Страница 23: ...Although all DOMOTIC series salt electrolysis units are SELF CLEANING a prolonged operation of the system at pH values over 7 6 in waters of high hardness can produce scale formation on the surface of...

Страница 24: ...until the pH screen 15 displays a blinking 7 0 3 Gently shake the sensor to remove any possible drops of water and insert in the standard pH 7 0 solution green Gently shake for a few seconds and pres...

Страница 25: ...ntroller will be determined in each particular application Nevertheless we recommend to make it at least once a month during the use period of the pool The ORP controller has an automatic calibration...

Страница 26: ...lay 21 will indicate E2 not allowing calibration If the ORP measure is unstable during the calibration process code E3 will appear in display 21 In addition the sensor calibration will not be allowed...

Страница 27: ...zer cyanuric acid until a concentration of 25 30 g m 3 is achieved pH ORP controller always show extreme values or readings are unstable The cable of the pH ORP sensor is damaged Clean the contacts or...

Страница 28: ...pump Electrolysis display card Electrolysis pH display card Electrolysis PH ORP display card Power transformer 190 VA Power transformer 370 VA Power transformer 480 VA Power transformer 490 VA Extern...

Страница 29: ...42 8 m3 h Electrode number Domotic Series 12 5 Domotic Series 24 7 Domotic Series 32 7 Domotic Series 42 13 Net weight packaging included Domotic Series 12 11 Kg Domotic Series 24 13 Kg Domotic Series...

Страница 30: ...29 Dimensions DOMOTIC DOM XX models DOMOTIC PH PLUS DOM XX PH and DOM XX PLUS models...

Страница 31: ...ve the buyer must closely follow the manufacturer s instructions included in the documentation supplied with the product as applicable to each product range and model 10 2 2 Whenever a schedule is def...

Страница 32: ...cambiare totalemente o parzialmente le caratteristiche technique dei nostri prodotti ed il cotenuto di questo docuemntosenza nessum preavviso Wir behalten uns das recht vor die eigenschatten unserer p...

Отзывы: