IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be implemented for 
installation and start-up. Therefore, the installer as well as the user must read the instructions before beginning installation and start-up. 
Keep this manual for future reference. 

 

 

Disposal of waste electrical and electronic domestic systems in the European Union 
 
All the products marked with this symbol indicate that the product shall not be mixed or disposed with your 
household waste at their end of use. It is responsibility of the user to eliminate this kind of wastes depositing them in 
a recycling point adapted for the selective disposal of electrical and electronic wastes. The suitable recycling and 

treatment of these wastes contributes in essential way to the preservation of the Environment and the health of the 
users. For further information regarding the points of collection of this type of wastes, please contact to the dealer 
where you acquired the product or to your municipal authority. 

 
The instructions given in this manual describe the operation and maintenance of DOMOTIC Series DOM-XX, DOM-XX PH and DOM-XX 
PLUS Salt Electrolysis Systems. For optimum performance of the DOMOTIC Series Salt Electrolysis Systems, we recommend you to follow 
the instructions given below: 
 
 
 
1.

 

CHECK THE CONTENTS OF THE PACK: ___________________________________________________________________________  

 
You should find the following elements inside the box: 
 

 

Power supply. 

 

Electrolysis cell. 

 

pH sensor (only in DOM-XXPH). 

 

EX-ORP sensor (only in DOM-XX PLUS Series). 

 

Calibration solutions pH 7.0 (green) / pH 4.0 (red) / ORP 470 mV (only in DOM-XXPH and DOM-XX PLUS models). 

 

Sensor holder (only in DOM-XX PH and DOM-XX PLUS models). 

 

CEE22 (M) connector for dosage pump (only in DOM-XX PH and DOM-XX PLUS models). 

 

Operation Manual. 

 
 
 
2.

 

GENERAL FEATURES: _________________________________________________________________________________________  

 
When DOMOTIC Series Salt Electrolysis System is installed, a quantity of salt must be dissolved into the swimming pool water. This salty 
water then passes through the electrolysis cell that is located in the plant room. The DOMOTIC Series Salt Electrolysis System consists of 
two elements: an electrolysis cell and a power supply. The electrolysis cell contains a quantity of titanium plates (electrodes) and when a 
weak electrical current is passed through the plates inside the electrolysis cell, there is chlorine production. 
 
Maintaining a level of chlorine in swimming pool water keeps the water sanitised and healthy to swim in. The DOMOTIC Series Salt 
Electrolysis System will manufacture chlorine whenever the pool circulation system (pump and filter) is operational. 
 
The power supply is provided with various safety devices, which are activated in case of irregular operation of the system, as well as a 
microprocessor driven control system. 

 
The DOMOTIC Series Salt Electrolysis Systems have an automatic cleaning system that avoids scale formation on the electrodes. Moreover, 
DOMOTIC-PH Series Systems include a built-in pH controller, as well as an additional ORP controller in the case of DOMOTIC-PLUS Series 
models. 
 
 
 
3.

 

SAFETY WARNINGS AND RECOMMENDATIONS: ___________________________________________________________________  

 

 

The equipment should be assembled and handled by truly qualified people. 

 

Current electrical and accident prevention regulations should be followed. 

 

Under no circumstances will the manufacturer be held responsible for the assembly, installation or start-up, nor any handling or 
fitting of components unless they are carried out on its premises. 

 

The DOMOTIC Series Salt Electrolysis Systems operate at 230VAC, 50/60 Hz. Do not attempt to alter the system to operate at a 
different voltage. 

 

Check that all the electrical connectors are well tightened to avoid false contacts and their consequent overheating. 

 

Before installing or replacing any component, disconnect the equipment from the mains, and use exclusively spare parts supplied 
by IDEGIS. 

 

Taking into account the fact that the equipment produces heat, it must be installed in places with sufficient ventilation. Fan 
openings should be kept free of any element that could obstruct them. The equipment should not be installed near flammable 
materials. 

 

The DOMOTIC Series Salt Electrolysis Systems have an IP24 protection degree. They should never be installed in places 
susceptible to flooding. 

 

 
 

Содержание DOM-12 PH

Страница 1: ......

Страница 2: ...This salty water then passes through the electrolysis cell that is located in the plant room The DOMOTIC Series Salt Electrolysis System consists of two elements an electrolysis cell and a power supp...

Страница 3: ...potential free contact for external flow detector and ORP RESIDUAL CHLORINE control Programmable contact logics from unit control panel Salt level protection Automatic production protection ELECTROLY...

Страница 4: ...3 Fig 1 Recommended installation diagram DOMOTIC Series DOM XX...

Страница 5: ...4 Fig 2 Recommended installation diagram DOMOTIC Series DOM XX PH and DOM XX PLUS...

Страница 6: ...of the cell should allow easy access to the installed electrodes by the user It is highly recommended to install the electrolysis cell VERTICALLY in a place of the pipe that can be easily isolated fro...

Страница 7: ...en the electrolysis cell and the power supply according to the following scheme Due to relatively high current intensity circulating do not modify or cut either the length or section of the supplied c...

Страница 8: ...13 Fig 12 Fig 13 4 5 Installation of the optional external flow detector not included with the equipment 1 Install the saddle supplied in a section of the pipe at the entrance to the electrolysis cell...

Страница 9: ...Fig 11 1 and sliding upwards and outwards Fig 11 2 Then turn the cover to the left Fig 11 3 and disconnect the communications bus A from power and visualization cards Fig 11 4 2 Unscrewing its four f...

Страница 10: ...9...

Страница 11: ...10 4 8 Controls and indicators DOMOTIC Series electrolysis systems are equipped with a control panel in the front Figs 15 16 16b Fig 15 DOM XX models control panel Fig 16 DOMXX PH models control panel...

Страница 12: ...tors DIRECT REVERSE polarity 11 Display of SYSTEM INFORMATION 12 Indicator of FLOW ALARM 13 Indicator of ELECTRODE passivation ALARM 14 Key increase production programming menu navigation 15 Display o...

Страница 13: ...ent input for potential free contact When the contact connected to this input is open external flow detector at rest and the FS is configured as FS1c the electrolysis system switches off due to the fl...

Страница 14: ...the minimum recommended level of salt 5 g l should be maintained by adding 5 kg per m 3 of water if the water did not previously contain salt Always use common salt sodium chloride without additives l...

Страница 15: ...s you to establish the following operative parameters MODEL domotic 12 domotic 24 domotic 32 domotic 42 SOFTWARE VERSION Shows software version two digits POLARITY SWITCH Switch every 2 hours 2 Switch...

Страница 16: ...15 Fig 23 System programming flow sheet...

Страница 17: ...tion value 4 could be lower than the programmed and displayed value 11 WINTER Mode during periods of low water temperature select a production level 1 in the 50 60 range 5 4 Salinity test The DOMOTIC...

Страница 18: ...OF THE PH ORP SENSORS models DOM XX PH and DOM XX PLUS Connect the pH ORP sensor provided with the unit to the corresponding BNC connectors located in the unit s base Fig 26 5 5 2 CONNECTION OF THE D...

Страница 19: ...the dosage pump which allows to avoid the following situations Damages caused by the dry operation of pump depleted pH minus product Over dosage of pH minus product damaged or aged sensor PH regulati...

Страница 20: ...VEL If there is less than the recommended salt content in the pool the selected output level cannot be reached The LOW SALT 6 light will stay on In this case measure the salt level in the water and ad...

Страница 21: ...System running 2 Gas detected Insufficient flow System off Fig 29 OPTIONAL EXTERNAL FLOW DETECTOR FLOW SWITCH not included with the equipment During the system configuration process point 5 2 the inpu...

Страница 22: ...due to excessive scaling on the electrodes when the system operates with hard water with a high pH value Fig 31 PH ORP OUT OF RANGE only in models DOM XX PH and DOM XX PLUS The integrated pH ORP contr...

Страница 23: ...Although all DOMOTIC series salt electrolysis units are SELF CLEANING a prolonged operation of the system at pH values over 7 6 in waters of high hardness can produce scale formation on the surface of...

Страница 24: ...until the pH screen 15 displays a blinking 7 0 3 Gently shake the sensor to remove any possible drops of water and insert in the standard pH 7 0 solution green Gently shake for a few seconds and pres...

Страница 25: ...ntroller will be determined in each particular application Nevertheless we recommend to make it at least once a month during the use period of the pool The ORP controller has an automatic calibration...

Страница 26: ...lay 21 will indicate E2 not allowing calibration If the ORP measure is unstable during the calibration process code E3 will appear in display 21 In addition the sensor calibration will not be allowed...

Страница 27: ...zer cyanuric acid until a concentration of 25 30 g m 3 is achieved pH ORP controller always show extreme values or readings are unstable The cable of the pH ORP sensor is damaged Clean the contacts or...

Страница 28: ...pump Electrolysis display card Electrolysis pH display card Electrolysis PH ORP display card Power transformer 190 VA Power transformer 370 VA Power transformer 480 VA Power transformer 490 VA Extern...

Страница 29: ...42 8 m3 h Electrode number Domotic Series 12 5 Domotic Series 24 7 Domotic Series 32 7 Domotic Series 42 13 Net weight packaging included Domotic Series 12 11 Kg Domotic Series 24 13 Kg Domotic Series...

Страница 30: ...29 Dimensions DOMOTIC DOM XX models DOMOTIC PH PLUS DOM XX PH and DOM XX PLUS models...

Страница 31: ...ve the buyer must closely follow the manufacturer s instructions included in the documentation supplied with the product as applicable to each product range and model 10 2 2 Whenever a schedule is def...

Страница 32: ...cambiare totalemente o parzialmente le caratteristiche technique dei nostri prodotti ed il cotenuto di questo docuemntosenza nessum preavviso Wir behalten uns das recht vor die eigenschatten unserer p...

Отзывы: