3.- SYSTEM DESCRIPTION
When an IDEGIS SALT ELECTROLYSIS SYSTEM is installed, a quantity of salt is dissolved
into the swimming pool water. This salty water then passes through the electrolysis cell that
is located in the plant room.
When a weak electrical current is passed through the plates inside the electrolysis cell,
chlorine is produced. Maintaining a level of chlorine in swimming pool water keeps the water
sanitised and healthy to swim in.
An IDEGIS SALT ELECTROLYSIS SYSTEM will manufacture chlorine whenever the pool
circulation system (pump and filter) is operational.
The IDEGIS
SYSTEM will also monitor the pH and activate a dosing pump to add pH
reducing chemical if necessary. Moreover, the integrated ORP controller will automatically
control the chlorine level in the water, connecting/disconnecting the electrolysis system when
necessary.
It is important to continue to test the pool water for chlorine, pH and Total Alkalinity, and to
adjust these values as required. The chlorine level can be increased via the integrated ORP
controller. The pH will be reduced by IDEGIS
SALT ELECTROLYSIS SYSTEM with
INTEGRATED pH/ORP CONTROL, and water balance must be maintained and adjusted
separately.
The IDEGIS SALT ELECTROLYSIS SYSTEM consists of two elements: an electrolysis cell
and a power supply. The electrolysis cell contains a quantity of titanium plates (electrodes), a
weak electrical current is passed through these plates and when a salt solution passes
though the cell, free chlorine is produced.
The power supply is provided with various safety devices, which are activated in case of
irregular operation of the system, as well as a microprocessor driven control system.
IDEGIS SALT ELECTROLYSIS SYSTEMS have an automatic cleaning system that avoids
scale formation on the electrodes.
12
Содержание D-10+
Страница 1: ...SALT ELECTROLYSIS SYSTEM D 10 EN D 18 D 25 D 40 integrated pH ORP controller OPERATION MANUAL D 40...
Страница 2: ......
Страница 4: ...7 PRACTICAL ADVICES 8 TROUBLESHOOTING 9 WARRANTY 35 36 38 2...
Страница 9: ...7...
Страница 23: ...5 1 3 RUN ORP CONTROL NOT ACTIVATED MANUAL MODE 21...
Страница 24: ...ORP CONTROL ACTIVATED AUTOMATIC MODE 22...
Страница 41: ...NOTES...
Страница 42: ...NOTES...
Страница 43: ......