Functions
74
HR9Z-B2202 8/2020
Configuring the Start Function
The start function is configured by means of the start function selector.
A start function with dynamization is typically if the start input is connected to a start push-button.
A start function without dynamization is typically used if the start input is connected to a logic
controller. Refer to the chapter Dynamization
) for details.
Position of start function selector
Configured start function
1
Automatic/manual start (depends on
sensor/device connected to start input)
Without startup test
With dynamization
2
Automatic/manual start (depends on
sensor/device connected to start input)
With startup test
With dynamization
3
Monitored start
Without startup test
With dynamization
4
Monitored start
With startup test
With dynamization
5
Automatic/manual start (depends on
sensor/device connected to start input)
Without startup test
Without dynamization
6
Automatic/manual start (depends on
sensor/device connected to start input)
With startup test
Without dynamization
7
Monitored start
Without startup test
Without dynamization
8
Monitored start
With startup test
Without dynamization
Содержание HR6S-S
Страница 1: ...http www idec com HR6S S Safety Module Original instructions HR9Z B2202 ...
Страница 8: ...8 HR9Z B2202 8 2020 ...
Страница 14: ...14 HR9Z B2202 8 2020 ...
Страница 20: ...Introduction 20 HR9Z B2202 8 2020 ...
Страница 56: ...Installation 56 HR9Z B2202 8 2020 ...
Страница 92: ...Accessories Service Maintenance and Disposal 92 HR9Z B2202 8 2020 ...