79
TILT-A-WAY HYDRAULIC VERTICAL PIVOT GATE
OPERATOR FIELD INSTALLATION
DRAWING # HYJG-241 PAGE 67
HYJG 1
REF. NO.
DESCRIPTION
Note: If gate does not operate on first try, but hydraulic pump runs
switch 2 power lines to reverse pump rotation
.
1.
Control pedestal
HYJG
2.
Concrete support slab Minimum dimensions 11’0” long x 4’0” wide x 1’6” thick.
To be placed on firm soil or compacted fill, reinforced with #4 rebar each way; and cement piling dug to frost
line by purchaser
NOTE: Will withstand and estimated 100 MPH wind in most soil conditions.
3.
Electrical conduit area. Stub in electrical supply, 20 Amp service.
4.
Four anchor bolts ¾” diameter X 12” with 2” projection.
5.
Two base plates, welded to pedestal.
____________________________________________________________________________________________
TILT-A-WAY
HYDRAULIC OPERATOR INSTALLATION PROCEDURE FOR GATE THAT IS
SHIPPED UNASSEMBLED
1.
Remove all materials used for protection during shipment.
2.
Place pedestal on concrete pad. Align and level pedestal, drill four holes minimum 10” deep. Epoxy ¾” x 12
studs in holes. Follow epoxy manufacturers instructions.
3.
Open rear access door to expose spring tension adjustment screws.
4.
Find two fluid bypass valves, place in open position.
5.
Back off spring tension screws to provide slack in tension cables. (1 5/8” socket needed)
6.
Rotate barrier carriage to down position. Remove pivot shaft with attached components. Install barrier and
secure to vertical carriage post with five bolts and one bolt at outer end of carriage horizontal channel.
7.
Place plastic rub washer over pivot shaft collar on carriage. Align cylinder rod end bearing with collar and
insert pivot shaft from far side. Secure with flat washer, lock washer and bolt.
8.
Tighten spring tension screws while inspecting cables for proper wrap around balance sheaves. When slide
members have reached marks indicated on tracks. Proper balance tension will have been achieved. If at a later
date minor adjustment should be required, refer to balance system adjusting section.
9.
Perform required electrical connections in accordance with diagrams shown in this manual.
10.
Position fluid bypass valves to closed setting, close and secure access door.
11.
If gate fails to function properly, contact manufacturer’s representative.
TILT-A-WAY
HYDRAULIC OPERATOR INSTALLATION PROCEDURE FOR GATE THAT IS
SHIPPED ASSEMBLED
1.
Remove all materials used for protection during shipment.
2.
Place operator and barrier on concrete pad. Align and level pedestal, drill four holes minimum 10” deep. Epoxy
¾” x 12 studs in holes. Follow epoxy manufacturers instructions.
3.
Perform required electrical connections in accordance with diagrams shown in this manual.
4.
Position fluid bypass valves to closed setting, close and secure access door.
5.
If gate fails to function properly, contact manufacturer’s representative.
Содержание TILT-A WAY HYJG 1
Страница 8: ...IDEAL MANUFACTURING INC 3 ALTERNATE FENCE SCHEMES HYJG 1...
Страница 14: ...UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 SINGLE GATE 24 VOLT DC IDEAL MANUFACTURINGINC 9...
Страница 15: ...UP DOWN ENT MAIN EXIT SUB ENT SUB SAVE TILT A WAY HYJG 1 MASTER GATE 24 VOLT DC IDEAL MANUFACTURING INC 10...
Страница 16: ...TILT A WAY HYJG 1 SLAVE GATE 24 VOLT DC IDEAL MANUFACTURINGINC 11...
Страница 20: ...TILT A WAY HYJG 1 SLAVE GATE 240 VOLT SINGLE PHASE IDEAL MANUFACTURING INC 15...
Страница 24: ...IDEAL MANUFACTURING INC 19 TILT A WAY HYJG 1 SLAVE GATE 240 VOLT THREE PHASE...
Страница 28: ...TILT A WAY HYJG 1 SLAVE GATE 480 VOLT THREE PHASE IDEAL MANUFACTURING INC 23...
Страница 44: ...TILT A WAY HYJG 1 ELECTRICAL LOOP WIRING IDEAL MANUFACTURING INC 39 HYJG 229 6 17 2015...
Страница 52: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Страница 53: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Страница 54: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Страница 55: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Страница 77: ...BLANK PAGE FOR NOTES...
Страница 86: ...MODEL HYJG HYDRAULIC VERTICAL PIVOT GATE IDEAL MANUFACTURING INC...
Страница 106: ...IDEAL MANUFACTURING INC Date 3 25 2016 HYJG 252 TILT A WAY HYDRAULIC VERTICAL PIVOT GATE HYDRAULIC SYSTEM HYJG 1 100...
Страница 123: ...ULT PLG Operating Instructions 49 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Страница 124: ...ULT PLG Operating Instructions 50 Document no 10180904 Revision 1 3 6 3 15 BLANK PAGE...
Страница 131: ...71 journaux d v nements General Event Log Event 1 most recent S curit Event Log Event 1 le plus r cent...