general
sTanDarDs anD safeTy insTrucTions
OVERVIEW OF EU STANDARDS
solar systems in general
en iso 9488
Thermal solar systems and components, terminology
(ISO/DIS 9488; 1995)
en 12975-1
Thermal solar systems and components - Collectors -
Part 1: General requirements
en 12975-2
Thermal solar systems and components - Collectors -
Part 2: Test Methods
env 1991-2-3
Eurocode 1 - Basis of design and actions on structures -
Part 2-3: Actions on structures - Snow Loads
en 12976-1
Thermal solar systems and components - Factory made systems -
Part 1: General requirements
en 12976-2
Thermal solar systems and components - Factory made systems -
Part 2: Testing Methods
env 12977-1
Thermal solar systems and components - Custom built systems
- Part 1: General requirements
env 12977-2
Thermal solar systems and components - Factory made systems -
Part 2: Testing Methods
iso 9459-1: 1993
Solar heating - Domestic Water heating systems - Part 1:
Performance rating procedure using indoor test methods
iso/Tr 10217
Solar energy - Water heating systems - Guide to material
selection with regard to internal corrosion
collectors and collector assembly
env 1991-2-4
Eurocode 1 - Basics of design and actions on structures -
Part 2-4: Actions on structures - Wind actions
lightning protection
env 61024-1
Protection of structures against lightning – Part 1: General
principles (IEC 1024-1: 1990; modified)
Building Regulation, dating from 1991 (England and Wales)
Requirement G3, L1 and Regulation 7
bs 7671
Requirements for electrical installations
(IEE Wiring Regulations, 16
th
edition
safe HanDling of subsTances
Heat Transfer fluid
Use undiluted only.
Keep out of reach of children.
Avoid contact with skin and eyes.
If swallowed, seek medical advice immediately and show the label
adhered to the container.
Disposal
Any packaging contaminated or not along with Ideal Solar fluid
must be disposed of at an appropriate waste site, whilst observing
local regulations.
planning permission
Planning permission for the Ideal Solar System is generally only
required if you are in a conservation area or you are installing a
solar system on a listed building.
However it is prudent to seek the opinion of the local authority on
planning matters prior to starting work on the solar installation.
insTallaTion requiremenTs
The installation of the Ideal solar system must be carried
out in accordance with the relevant requirements for safety,
current Wiring Regulations, local Building Regulations, Building
Standards (Scotland), (Consolidation) Regulations and Bylaws
of the local water company and Health and Safety document No.
63S (Electricity at Work Regulations 1989).
It should be in accordance with the relevant recommendations of
the following British Standards and Regulations:
· BS 5918:1989
· The Health and Safety at Work Act 1974
· The Management of Health and Safety at Work Regulations
1999
· The Construction (Health, Safety and Welfare) Regulations
1996
· The Construction (Design and Management) Regulations
1994
· The Lifting Operations and Lifting Equipment Regulations
1998
The manufacturer’s notes must not be taken in any way as
overriding statutory regulations.
elecTriciTy supply
All wiring must be performed in accordance with BS7671:
Requirements for Electrical Installations (IEE Wiring Regulations,
16
th
Edition).
A 3 amp fused three pin plug and un-switched shuttered socket
outlet (both complying with BS 1363) or preferably a double pole
isolator with a contact separation of 3mm in all poles supplying
the controller should be used. The controller must be earthed.
earth bonding
Ensure that the primary flow and return circuit is electrically
cross-bonded in accordance with BS 7676.
WarranTy
The Ideal Solar system is supplied with a Comprehensive
Warranty cover of 10 years for the solar collector(s) and 2 years
for the pump station and controller.
For one off installers - products are sold with materials only
warranty
For Developers - Materials only warrantly. If labour required, to
be arranged and priced with the installer.
Ideal Solar Technical Support Line: 01482 498307.
HeaT Transfer fluiD
Solar panel collectors and system components should be used only
with the recommended heat transfer fluid as supplied in the kit.
Recommended fluid is supplied as:
10 Lt Container - Part No. UIN 206536
20 Lt Container - Part No. UIN 206537
25 Lt Container - Part No. UIN 206538
The heat transfer fluid uses a proven concentration of anti-
freeze and water to give protection against freezing and provide
optimum performance from the solar panel collectors and system
components. Additional fluid can be obtained via Ideal Solar
stockists.
The fluid is pre-mixed to 60% concentration and is suitable for flat
plate and vacuum tube collectors.