insTallaTion
Solar Thermal -
Installation and Servicing
ins
T
alla
T
ion
8 mounTing sysTem, parallel
General Note:
Points 8-11, 16 and 17 of these instructions only apply when mounting more than two collectors.
1. Measure distance between mounting bracket.
Distance should be between (125 - 155cm).
Remove appropriate roof tiles to fit roof bracket
console.
2. A = 125 - 155cm - Distance between brackets
3. Fasten roof bracket console to rafters with provided self
tapping screws 6 x 60
4. Replace roof tile, cut tile to ensure correct fit if necessary.