19
Capacitance Measurements
Range
Resolution
Accuracy
Accuracy
(61-633)
(61-635)
4nF
1pF
±(1.9% +20)
±(0.9% +20)
40nF
10pF
400nF
100pF
4µF
1nF
40µF
10nF
±(2.9% +20)
±(1.9% +20)
400µF
100nF
4mF
1µF
±(3.9% +20)
±(2.9% +20)
10mF
10µF
To Measure Capacitance:
1. Turn the power off to the cir-
cuit or device that is to be
measured and discharge all capacitors before attempting a
measurement.
2. Plug the Black test lead into the COM port and the Red test
lead into the V
Ω
port.
3. Set the rotary switch to the µ position.
ND 2352-1 61-633 630 Series Ins 12/22/04 9:49 AM Page 19