The height of every column (4, 1, 3, 2 in the LCD12th) is memorized as the
customized zero points.
Note:
1) The customized zero-point height reference can only be performed just after
LCD screen 9th display.
Any lifting operation (UP, DOWN, PACK) in MODE
ALL or AXLE will cancel the performance and keep the reference system to
be UNIFORM immediately.
2) Under customized zero-point height reference, if all columns’ height are below
theirs customized zero points and at least one column within 6” (150mm) to
the ground, the reference will be back to uniform reference, SINGLE and the
‘Z___’ will be on the screen again.
3) So, to change the height reference system (also travel distance or height unit)
second time, operator shall wait all lifting forks in lowest (ground) position and
the LCD screen is 9
th
again.