background image

10 

Mar 2016 

MSC-18K 

 

3.2    CONTROL PANEL DETAILS   

1. EMERGENCY button 
 

To stop movements (lifting or lowering) immediately. 

2. POWER switch 
            Controls the power of the control panel or charging of the batteries. 

3.    ‘

⇑⇑

⇑ ’’’’

( UP ) button 

 

Controls the lifting of the columns. 

4.    ‘

⇓⇓

⇓ ’’’’

( DOWN ) button 

 

Controls the lowering of the columns. 

5.    ‘

⇓⇓

⇓ ’’’’    

( PARK ) button 

 

Controls the locking of the columns. 

6. POWER light. 
 

This light will go on when the control panel is power on. 

7. 8. 9. 10. CURSOR buttons. 
 

These buttons move cursor on the screen to edit items. 

11. 12. 13. MODE buttons. 
  

To select between the functions: “WHEEL”, “AXLE” & “ALL” 

14. BIAS button 
  

To set the zero point of height in initialization. 

15. START button 
 

To start the running of the software. 

16. SHIFT button. 
 

This button is for the running of the program. 

17. ENTER button 
 

This button serves confirming of instruction or entering sub menu. 

18. ESC button 
  

Serves to enter or exit from menu; or from sub menu to upper lever menu. 

19. LCD SCREEN 
 

Display the height readings of columns & information 

20. WARNING light 
 

This light will go on when the EMERGENCY button is pressed. 

21. CABLE port 
 

This port is used for communication cable connection. 

22. BATTERY indicator 
 

This indicator shows the output voltage of the batteries. 

23. HAND / REMOTE CONTROLLER port 
 

The port is for hand/remote controller connection 

Содержание MSC-18K-B

Страница 1: ...el i f t i n gf o r k s a c c o mmo d a t et h ew i d e s t r a n g eo f w h e e l s E a s i l y p o s i t i o n e dw i t hp a l l e t j a c k s t y l ew h e e l H e a v y d u t y h y d r a u l i c s...

Страница 2: ...2016 Mar Mobile Column Lift Set MSC 18K B Capacity 18 000lbs Each Column Installation Operation Service Manual...

Страница 3: ...COLUMNS PAGE 29 CHAPTER 10 HAND CONTROLLER Optional PAGE 30 CHAPTER 11 BATTERY CHARGER INFORMATON PAGE 31 CHAPTER 12 BATTERY REQUIREMENT INFORMATION PAGE 32 CHAPTER 13 EXPLODED VIEWS PARTS LISTS PAGE...

Страница 4: ...er supply Input 100 140 60Hz single phase Output 24VDC Max 15Amper Operational Voltage 24 VDC Lifting Height 67 1 Column L W H 56 9 44 1 88 6 Max Ht 146 7 Fork Adjustable Range 12 6 22 Fork length 17...

Страница 5: ...4 Mar 2016 MSC 18K 1 2 DIMENSIONS mm inch Fig 1 Mobile Column Lift Dimensions...

Страница 6: ...But at least two lifting columns are required to work at same time for lifting a vehicle The main components of the mobile column lift are shown below see figure 2 1 Height sensor encoder 2 Safety lo...

Страница 7: ...INFORMATION sections Pallet Jack Mechanism The two wheel pallet jack mechanism serves to move the lifting column The two wheels protect the lifting column from being turned over at the back when it i...

Страница 8: ...is mobile column lift can only be operated or installed indoors When under environment of temperature within 0 40 moisture 85 the lift will work reliable and longer time B Never set up the lifts on an...

Страница 9: ...he cable reels from the carton 2 Insert the holding frame into the base on the upper cover Figs 6a b Fig 6a Fig 6b Fig 6c 3 Pull up and pull down the upper and down lock button the reel can turn aside...

Страница 10: ...Control Panel controls the main power All other functions of the lifting system are controlled by the Control Panels on the columns The functions of the switches buttons on the control system are desc...

Страница 11: ...functions WHEEL AXLE ALL 14 BIAS button To set the zero point of height in initialization 15 START button To start the running of the software 16 SHIFT button This button is for the running of the pr...

Страница 12: ...in column 1 should be located opposite with column 2 loading the same axel of the vehicle The 4 shall be at the other end of the same axel with 3 Fig 8 A set has a maximum lifting capacity of 52 800 l...

Страница 13: ...ns as indicated in 4 3 Fig 8 2 Then turn on the battery power switch of each column on the side Fig 9a Fig 9a Fig 9b 3 Set the control box power switch Fig 9b on each sub column to left position ON fi...

Страница 14: ...of button is pressed When the Mode is ALL Vehicle II II Press one button will cause all columns moving When the Mode is WHEEL Single I Press one button will cause only that columns moving When the Mod...

Страница 15: ...nit Stroke as in LCD screen 6th 4 Press ENTER button again to enter the unit and travel distance modification screen LCD screen 7th 5 To change the unit using DIRECTION UP and DOWN buttons to change t...

Страница 16: ...ll for cable model 4 5 3 CUSTOMIZED HEIGHT REFERENCE If for any reason the height of different column shall be kept differently difference is greater than 2 50 mm the Customized height reference shall...

Страница 17: ...and keep the reference system to be UNIFORM immediately 2 Under customized zero point height reference if all columns height are below theirs customized zero points and at least one column within 6 1...

Страница 18: ...ion 1 Lift lock pin to unlock the fork 2 Use both hands to slide the fork sideways Adjust both forks so that they are equally spaced in relation to the centre of the column 3 Adjust so that the forks...

Страница 19: ...its neutral position The pallet jack mechanism is lowered and the lift will sit on ground Fig 11 Pallet Lifting Steps to move the column lift with pallet jack 1 Pull up the lever to position 1 and ma...

Страница 20: ...t jack mechanism is fully lowered before lifting a vehicle 4 1 PREPARATION IMPORTANT NOTICE 1 Place all the four of lifting columns around the vehicle as in Fig 8 2 Ensure that the fork of each liftin...

Страница 21: ...mn 2 or both 1 and 2 are quick in rising or lowering The height difference is greater than 3 4 20mm the column s will be slowed down automatically 2 Suspending Or Both column 1 and 2 are quick in risi...

Страница 22: ...o be pressed one time 4 4 EMERGENCY STOP AND LOWERING In emergency situations it is possible to stop the lifting columns manually by pushing the emergency button NOTE If the motor keeps running after...

Страница 23: ...icient After moving stopped one or more columns were found battery in low voltage The lift will not raise up any more but may lower down 5 Locked by abnormal ope One button is pressed within 2 after p...

Страница 24: ...rage place 5 1 CHARGING BATTERIES After one day s operation or the battery indicator shows the voltage is low it is suggested to charge the batteries Different batteries need different charging time P...

Страница 25: ...ONTHLY BY OPERATOR Check hydraulic fluid level and replenish as necessary Check the emergency release mechanism 1 Push the emergency stop button when the columns are moving All the columns should stop...

Страница 26: ...isplaying following to remind user to do the filer clearing of the valves and hydraulic oil changing LCD display 18th And also while the time reaches 3600 minutes it will appear again To continue oper...

Страница 27: ...ence If the defect occurs again contact the service department Column Does not Lower Battery voltage is too low Charge the batteries Catching pawl not disengaged from locking system Raise column appro...

Страница 28: ...r zero point not correct Do encoder alignment No Control Power Fuse blown Check the fuses F1 F2 and F3 If necessary replace the fuse s in the control box If fault occurs again contact the Service Depa...

Страница 29: ...ch column If any one is not between 1 and 7 adjustment shall be done LCD screen 14th 6 To adjust please open the upper cover on the column Then separate the strip from the gear of the sensor 7 Turn th...

Страница 30: ...p 2 Turn off the power switch of each control units Step 3 Disconnect the cable between column 1 3 2 4 Step 4 Turn on the power switch of the control unit on desired columns 2 and 1 again Step 5 After...

Страница 31: ...ig 11 The hand controller has one EMERGECY button and UP DOWN PARK buttons Fig 11 Fig 12 Every control box on column has a special plug port for the hand controller Fig 12 Operator can put the hand co...

Страница 32: ...00 150 60 mm 7 Weight 850g 11 2 Panel of Charger 1 Charging indicator 2 Power indicator 3 Output cord 4 Power input socket 11 3 LED Performance Indicator on the charger 1 After the charged is power on...

Страница 33: ...t off the lift then charge the batteries at once Continue to use the batteries will short the life of batteries 2 Charge the batteries immediately after the job is finished This will help to prolong t...

Страница 34: ...33 Mar 2016 MSC 18K MSC 18K B EXPLODED VIEWS PARTS LISTS MSC 18K Column Assembly...

Страница 35: ...02 10035 000 bolt 1 17 DJ02 19003 A00 right side plate 1 18 5115 06012 000 screw 40 19 5110 06045 000 Screw 2 20 DJ02 00018 A00 switch knob 1 21 DJ02 00017 A00 switch panel 1 22 5110 05014 000 screw 9...

Страница 36: ...bolt 1 51 DJ02 00031 000 coil fixing board 1 52 5107 03010 000 screw 4 53 5306 00008 000 spring washer 5 54 DJ02 00008 000 lock tongue 1 55 5402 04030 000 cotter pin 1 56 DJ02 01000 A00 Column 1 57 DJ...

Страница 37: ...7 DJ02 06007 000 Pin 4 81 8 DJ02 06100 000 Wheel frame big 2 81 9 DJ02 06006 000 Spring seat 2 2 81 10 DJ02 06005 000 Spring 2 81 11 DJ02 06004 000 Spring seat 1 2 81 12 5301 00014 000 flat washer 2 8...

Страница 38: ...er 4 107 DJ02 05011 000 oil screw 1 108 DJ02 05010 000 connector 1 109 DJ02 05008 000 Oil fitting 1 110 DJ02 00027 000 cylinder fixing board 1 111 5105 08025 000 Hexagonal screw 1 112 DJ02 05003 000 P...

Страница 39: ...38 Mar 2016 MSC 18K MSC 18K Control Panel Assembly...

Страница 40: ...6 50700 000 communication cable 3 14 5202 00003 000 nut 6 15 DJ04 20001 100 power switch 1 16 DT01 06023 000 cable nut 2 17 QK04 00011 000 cover 2 18 JK01 00003 000 cable nut 6 19 DJ02 00200 000 elect...

Страница 41: ...40 Mar 2016 MSC 18K MSC 18K Power Unit Assembly...

Страница 42: ...8 5109 10010 000 threaded pin 1 9 BZ22 00003 000 joint 1 10 5901 00277 000 O ring 1 11 5901 00925 000 O ring 1 12 BZ01 03000 000 gear pump 1 13 BZ20 01000 000 sucking pipe 1 13 1 BZ01 01002 000 mesh 1...

Страница 43: ...dered a warranty issue and therefore must be noted for any potential recovery with the shipping company The customer is required to notify Tuxedo of any missing parts within 72 hours Timely notificati...

Отзывы: