INSTALLATION
15 WATER CONNECTIONS
REAR FLUE OUTLET
DHW CONNECTIONS
CH CONNECTIONS
For top connections:
Use straight pipe and elbow (not supplied)
For top connections:
Reverse 15mm pipe
Extend a gas supply pipe of not less than 22mm
O.D. copper or 3/4" BSP iron to the boiler.
A working gas pressure of 20mbr (8" w.g) must be
avilable at the boiler inlet, with the boiler firing at full
DHW output..
Note.
Do not subject any of the isolating valves to heat as the seals may be damaged.
16 GAS CONNECTION
Bottom and top connections
1.
Solder the
1/2
" connector, street elbow, straight pipe and
reducing coupling together.
2.
Remove the gas cock bracket complete with gas cock.
3.
Screw the connector into the gas cock in the correct
orientation.
4.
Screw the complete assembly back onto the mounting
frame.