44
mexico HE
-
Installation & Servicing
Servicing
69 CONDENsATE ‘s’ TRAp REpLACEMENT & CONDENsATE pUMp (IF FITTED)
1.
Refer to Frame 51.
2.
Remove the boiler front panels. Refer to Frame 44.
3.
Condense pump removal (if fitted):
a.
Disconnect the outlet pipe rubber connecting joint
taking care to capture any liquid held in the pipe.
b.
Lift the inlet pipe to clear the pump.
c.
Remove the pump wiring cover.
d.
Remove the 5 wires from the terminal strip.
e.
Lift the condensate pump from the two screw
fixings.
f.
Pull the pump forward and remove the wiring
through the top grommet.
4.
Undo the plastic union nut on the condensate ‘S’ trap
outlet and disconnect the flexible hose.
5
. Remove the screw retaining the ‘S’ trap bracket and
remove the bracket.
6.
Loosen the top nut on the ‘S’ trap then pull the trap down
and forward to remove.
7.
Reassemble in reverse order, ensuring the condensate
pump is correctly replaced.
8.
Check operation of the boiler. Refer to Frame 51.
s
ER
VICIN
g
3b
Inlet pipe
from ‘S’ trap
Outlet pipe
3e
4
5
3a
6
3c
Содержание he15
Страница 2: ...2 mexico HE Installation Servicing...
Страница 50: ......