22
mexico HE
-
Installation & Servicing
InstallatIon
FLUE OUTLET
Measure from
this
RING
1
2
mxhe7843
1.
Fit the inner flue extension duct onto the inner
flue duct.
2.
Fit the outer flue extension duct onto the
outer air duct.
3.
Repeat steps 1 and 2 if a second flue
extension is required.
4.
Measure and mark the flue length
required onto the flue, measuring
from the ring near the terminal.
(Refer to Frames 19 and 23 for
detail of length measurement)
5.
To ensure a square cut, mark the
flue all the way around.
6.
De-burr the cut edges.
26 FITTINg ThE KIT
27 FITTINg ThE OpTIONAL FLUE FINIshINg KIT AND OpTIONAL Rs sEALINg pLATE
Flue Finishing Kit
1.
Fit black outer wall seal over terminal and ensure the retaining rim is
located in the terminal depression.
2.
Fit flue pipe assembly through the hole previously cut in wall.
3.
Fit white inner wall seal to pipe assembly (side flue).
4.
Fit outer wall sealing plate over outer wall seal and retain with the 4
screws and wall plugs provided.
Contents
:
Wall Seal White - 1 off
Wall Seal Black - 1 off
Wall Sealing Plate - 1 off
Screws No. 10x2” - 4 off
Wallplugs - 4 off
Rs sealing plate
If the mexico HE is replacing a room sealed
appliance, an optional extra terminal wall sealing
plate is available to make good the rectangular
flue hole.
Contents
:
Wall Seal plate - 1 off
Screws No. 10x2” Woodscrew - 4 off
Wallplugs - 4 off
3
1
4
mxhe7984
L of boiler
350 mm
C
690m
m
400 mm
mxhe7985