7. Power Unit Priming Procedure
THE PROBLEM:
Power unit runs fine but will not pump any fluid.
WARNING!! Failure to properly relieve hydraulic pressure in the following steps
can cause injury to personnel.
Step 1
– Locate the check valve, the flush plug to the left of the lowering valve.
Step 2
– Using an Allen wrench and shop towel – with shop towel in place to catch fluid
– loosen the check valve plug 2-½ turns to allow it to leak.
Step 3
– Push the START button for one second, then release for three seconds. Repeat
these steps until unit starts pumping fluid.
Step 4
– Tighten the check valve plug.
YOUR POWER UNIT SHOULD NOW BE PRIMED & READY TO GO!