EVOMAX 

User’s

 

CAutIon. 

 

to avoid the possibility of injury during the installation, servicing or cleaning of 

this appliance care should be taken when handling edges of sheet steel components.

All 

Gas Safe Registered Engineers 

carry a Gas Safe Register ID card, and have a registration number.  

Both should be recorded in your Log Book. You can check your installer by calling Gas Safe Register direct on 0800 4085500.

Introduction

The

 EVomAX 

is a wall mounted, room sealed, super efficient 

condensing boiler featuring full sequence automatic spark ignition 

and fan assisted combustion.

Due to the very high efficiency, condensate is produced from the 

flue gases and this is drained to a suitable disposal point through 

the plastic waste pipe at the bottom of the boiler.  A condensate 

‘plume’ will also often be visible at the flue terminal.

Safety

Current Gas Safety (Installation & use) 

Regulations or rules in force.

In your own interest, and that of safety, it is the law that this boiler 

must be installed and maintained by a Gas Safe Registered 

Engineer or in IE a competent person, in accordance with the 

above regulations.

The appliance should be serviced at least once a year by a Gas 

Safe Registered Engineer or in IE a competent person.

It is essential that the instructions in this booklet are strictly 

followed, for safe and economical operation of the boiler.

Electricity Supply

The appliance must be earthed.

Supply 230 V - 50 Hz.    The fusing should be 3A (5A for 100).

This appliance is intended to be connected to the supply via a 

double-pole switch, having a 3mm contact separation in both 

poles, serving only the boiler and system controls. Alternatively, a 

3-pin UNSWITCHED socket may be used. 

Important Notes

•  This appliance must not be operated without  

the casing correctly fitted and forming an adequate seal.

•  If the boiler is installed in a compartment then the 

compartment MUST NOT be used for storage purposes.

•  Do not store objects around or on the boiler, and keep access 

clear at all times.

•  Do not obstruct ventilation ducts, grilles or openings in the 

boiler room, room space or compartment that the appliance is 

installed in, or the passage of combustion and ventilation to 

the boiler.

•  Do not turn off the boiler if it is to be left unattended in frosty 

weather.

•  If it is known or suspected that a fault exists on the boiler then 

it MUST NOT BE USED until the fault has been corrected by a 

Gas Safe Registered Engineer or in IE a competent person.

•  Flammable materials must not be placed in close proximity to 

the appliance. Materials giving off flammable vapours must not 

be stored in the same room as the appliance.

•  This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, 

or lack of experience and knowledge, unless they have 

been given supervision or instruction concerning use of the 

appliance by a person responsible for their safety.

•  Children should be supervised to ensure that they do not play 

with the appliance.

In cases of repeated or continuous shutdown a Gas Safe 

Registered Engineer or in IE a competent person should be called 

to investigate and rectify the condition causing this and carry out 

an operational test after each intervention on the device. Only the 

manufacturers original parts should be used for replacement.

minimum Clearances

Clearances of 

300mm (12”)

 below, 

25mm (1”)

 at the sides and 

450mm (17 3/4

”) at the front of the boiler casing must be allowed 

for servicing.

to light the boiler  

(Refer to frame 1)

1. 

CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER 

IS OFF.

2.

  Set the boiler to standby.

3.

  Switch on the electricity supply to the boiler and check that all 

external controls, e.g. programmer, room thermostat, etc are 

on.  Allow the boiler to carry out a self check.

4.

  Set the boiler to winter.

The boiler will commence the ignition sequence, supplying heat to 

the system when required.

EVomAX
30, 40, 60, 80, 100, 120, & 150

30P, 40P, 60P & 80P

Natural Gas & LPG

PI No. 86 CL 166

Destination Countries: GB, IE