- 20 -
X
N
D O
M
b
c
•
Operation
•
Operating elements
A
- Safety light beam
B
- Safety two-handed control system
clamping and cutting
C
- Air table On-Off
D
- Backgauge control
E
- Foot pedal
F
- Main switch
G
- Hand-wheel for backgauge setting
H
- Key switch
I
- Backgauge
J
-
Side lay left and right
K
- Clamp pressure adjustment
L
- Paper knock-up block
Start machine
•
Main switch
F
to position "I".
Start screen appears
The following functions are changeable:
Brightness
CM/INCH
Touchtone volume
Language
Display / status photocell
b
green - red
Clamping pressure
c
•
Press START
M
backgauge
I
moves
to the rear and searches for the reference
position, wait until a measurement
is shown in the display
D
7260 = 72.00 cm, 28.346 inches
•
The DIN and free programmable
measurements are recallable with the
respective buttons
X
.
Memory 1: A2, A3, A4, A5,
Memory 2: A6, A7, B3, B4
Memory 3:
Memory 4:
and in inch
Memory 1: 4¼“, 5 ½“, 7“, 8 ½“
Memory 2: 11“, 12“, 14“, 17“
Memory 3:
Memory 4: