background image

HALO COMBI WI-FI

Product Code: 222142

Internet connected wireless single zone combi 

Programmable Room Thermostat (PRT)

ERP Class VI Compliant

Compatible with the following boilers serial letter 

code AFQ onwards: Logic Combi C, Logic Combi 

C IE, Logic Combi ESP1, Logic Code Combi ESP1, 

Logic+ Combi C, Logic Max Combi C, Logic Max 

Combi C IE, Vogue Gen2 Combi, Vogue Max 

Combi, Vogue Max Combi IE. 

To install Halo with older boilers a separate bracket 

is required (Product Code: 220366), for further 

details on the compatibility of older boilers with 

Halo plus installation details please go to 

www.idealboilers.com 

 

The Ideal Halo Combi Wi-Fi is a wireless PRT that 

is paired with the Halo Smart Interface installed in 

the boiler. The Halo Smart Interface plugs into the 

front aperture on the boiler and communicates 

to the boiler via OpenTherm. The Halo unit is 

powered by 4 AA batteries and communicates 

with the Smart Interface through Zigbee, a local 

RF protocol. 

The Smart Interface is Wi-Fi enabled and can be 

linked to the home Wi-Fi network to allow app 

controlled heating through the Halo app. 

SAFETY INFORMATION

The Ideal Halo Combi Wi-Fi must be installed 

by a competent person with the appropriate 

safety qualifications. Please read the instructions 

carefully. Failure to follow these instructions 

can damage the product or cause a hazardous 

condition.

These instructions are applicable to the Ideal 

Boiler models stated and must not be used with 

any other make or model of boiler. This product 

must be installed to all applicable standards.

Always isolate the mains supply before installing or 

working on any components relating to the boiler 

electronics. 

GETTING STARTED

The Halo app is available to download from the 

Apple App Store and on Google Play. To save time 

the householder may want to download the app 

and set up the account whilst the thermostat is 

being installed.

Содержание 222142

Страница 1: ...w w w i d e a l b o i l e rs com Halo Combi W i Fi I n s t a l l a t i o n G u i d e ...

Страница 2: ...The Halo unit is powered by 4 AA batteries and communicates with the Smart Interface through Zigbee a local RF protocol The Smart Interface is Wi Fi enabled and can be linked to the home Wi Fi network to allow app controlled heating through the Halo app SAFETY INFORMATION The Ideal Halo Combi Wi Fi must be installed by a competent person with the appropriate safety qualifications Please read the i...

Страница 3: ... Name Halo Combi Wi Fi Model Qualifier ErP Class VI I certify that the boiler is connected to an enhanced load compensator and weather compensator Class VI provided via the internet This product is compatible with the boiler and provides compensation control that has been permanently enabled The boiler has been commissioned in accordance with the manufacturer s instructions which have been supplie...

Страница 4: ...sider using the Ideal Zigbee Booster Product Code 221132 or mounting the Smart Interface externally to the boiler using a bracket Product Code 220366 Further details on this at www idealboilers com The Halo control system connects to the home Wi Fi network through a Wi Fi chip in the Smart Interface The home Wi Fi router should be positioned no more than 30 metres from the Smart Interface Where po...

Страница 5: ...using and clip into place 2 If no trim plate is required use the rear housing of the Halo to position the unit on the wall alternatively secure rear housing to trim plate Take care not to overtighten the screws C INSTALLATION OF THE HALO The Halo can be either wall mounted or desk mounted Wall mounting the Halo If there are any concerns regarding signal strength and location of the wall mounted Ha...

Страница 6: ...ed rear housing and desk stand 2 Insert the 4 AA batteries provided into the front housing of the Halo Pay close attention that the orientation of the batteries is as indicated in the housing 3 Clip the combined rear housing and desk stand into place ...

Страница 7: ...rm connection see diagram On brand new boilers the link should already be in place 2 Locate the wiring terminals 230V connections are on the left and low voltage on the right 3 If existing 230V device is already installed remove wiring from the 230V connections and add the link wire into the room stat timer connection see diagram On brand new boilers the link will already be in this position Link ...

Страница 8: ...n the aperture 8 Push fit the Halo Smart Interface into the boiler aperture 5 Locate the blanking plate on the front of the boiler and remove carefully with a small flat bladed screwdriver 6 Remove link wire plug and keep in a safe place Link wire plug Blanking plate ...

Страница 9: ...tch off the boiler the Override LED should now go out 11 Press and hold the Pair button on the Smart Interface until the Zigbee LED starts flashing red to begin the pairing process with the Halo 9 Switch on the boiler the Halo Smart Interface will power up and begin setup this can take up to 90 seconds Once setup is complete the green Power LED should be the only LED illuminated ON ...

Страница 10: ...lete when the Halo has successfully connected to the Smart Interface 5 The device will automatically prompt set up of the time and date 6 There is the opportunity to add an installer contact phone number into the device at this stage if not changed this will default to the Ideal Boilers Customer Service number 7 The home screen will be displayed showing the current and target temperature and the t...

Страница 11: ...ount has been set up the app will automatically guide the user through connection of the Halo This will involve using the app to link the Halo Smart Interface to the home Wi Fi network by following the instructions on the screen 6 The householder will need the name of their home Wi Fi network and the password or network key to complete the setup Minimum operating requirements Smart Phone Tablet iO...

Страница 12: ...tent person Landlord settings Specific settings for landlords Override and Failsafe only active when communication is lost between Halo and Halo Smart Interface See Halo User Guide for more information SMART INTERFACE LED KEY LED Status Power Green Power ON No illumination No Power Boiler Green Demand No illumination No Demand Connectivity No illumination Cloud connection not configured Red No con...

Страница 13: ...perature at the time specified OFF Delayed start If the room temperature is close to target temperature the heating start time is delayed to save energy OFF Display tolerance Select the display tolerance of the room temperature this can be set at increments of 0 5 or 0 1 C 0 1 C Temperature offset Fine tune the room temperature display 2 5 to 2 5 C 0 Daylight saving time Automatically move to dayl...

Страница 14: ...ss connection via support page on the PRT access via the menu Target RSSI between 0 and 65 and text green Check RSSI Received Signal Strength Indication of the Zigbee wireless connection and the Wi Fi connection via the support information in the Halo app Target RSSI between 0 and 65 and text green On the Halo set the mode to AUTO then increase the temperature to 30 C repeat using Halo app Flame O...

Страница 15: ... the target temperature is above current temperature Check Smart Interface power LED is green Check Smart Interface is securely plugged into boiler aperture Halo screen shows failed to pair Check Smart Interface is in paring mode Zigbee LED flashing red Check distance between Smart Interface and Halo see section B Reset Smart Interface by inserting a paperclip or pen tip into reset button Start pa...

Страница 16: ...sing a Wi Fi Booster or mounting the Smart Interface externally to the boiler using a bracket further details on www idealboilers com Deleting Halo from the Zigbee Network On the Halo press the dial and the right hand key together for 15 seconds this will delete the Halo from the Zigbee network and factory reset the device Deleting Zigbee Network To delete all devices from the Zigbee network press...