EXAMPLES OF ERRORS
Pairs or pins with errors are shown in red.
Item
Description
1
Short-circuit
2
Discontinuities
3
Line crossed
1.
Select Fault to view detailed test results.
6.4
Testing a passive route without Active Remote
The LanXPLORER can generate a low and a high tone and a
warbling tone which alternates between the low and high tone
at a rate of 2 Hz and can be recognized by the majority of
common line testers (e.g. IDEAL No. 62-164 Tone Probe).
Item
Description
1
LanXPLORER
2
Patch Cord
3
Wall Outlet
4
Patch Panel
5
Inductive receiver (tone probe)
PERFORMING TEST
1.
Connect the free end of the cable path to the RJ45 network port on the
LanXPLORER.
2.
Select the menu point "Tests" on the standby screen
.
3.
Select the menu point "ToneGen".
4.
Find the open end of the cable path with an inductive receiver (tone probe)
along the cable connected to the LanXPLORER.
Figure 59: Typical use of tone
generator