background image

4

INTRODUCTION

The Vogue Combi IE GEN2 is a wall mounted, room sealed, condensing combination boiler, featuring full sequence automatic 

spark ignition and fan assisted combustion.

Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point 

through a plastic waste pipe at the base of the boiler.  A condensate ‘plume’ will also be visible at the flue terminal.

The 

Vogue 

is a combination boiler providing both central heating and instantaneous domestic hot water.

SAFETY

Current Gas Safety (Installation & Use) Regulations or rules in force.

In your own interest, and that of safety, it is the law that this boiler must be installed by a Gas Safe Registered Engineer, in 

accordance with the above regulations.
In IE, the installation must be carried out by a Registered Gas Installer (RGII) and installed in accordance with the current edition 

of I.S. 813 “Domestic Gas Installations”, the current Building Regulations and reference should be made to the current ETCI 

rules for electrical installation.

It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.

FOR ANY QUERIES PLEASE RING THE

IDEAL CONSUMER HELPLINE : 01482 498660

NOTE. BOILER RESTART PROCEDURE - 
To restart the boiler, press “RESTART” hot key located below the colour screen.  The appliance will now repeat 

the ignition sequence if a heat demand is present.

Содержание VOGUE COMBI C26IE

Страница 1: ...any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been c...

Страница 2: ...2...

Страница 3: ...roduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and effic...

Страница 4: ...terest and that of safety it is the law that this boiler must be installed by a Gas Safe Registered Engineer in accordance with the above regulations In IE the installation must be carried out by a Re...

Страница 5: ...en supervision or instructions concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance In cases of rep...

Страница 6: ...cation Legend BOILER CONTROLS 1 0 4 2 3 bar MENU READY TIMER OR ROOM THERMOSTAT OFF ON 60 C off max max boiler off D H F G A B C E D Hot Keys E Central Heating Temperature Control F Domestic Hot Water...

Страница 7: ...ral heating if required Note In normal operation the boiler colour screen will display the boiler operation mode Boiler frost protection boiler will fire if temperature is less than 5 degrees C During...

Страница 8: ...mobilised refer to page 20 This will stop the boiler operating periodically for short periods This facility is primarily provided for boiler installations in a sensitive area i e bedroom etc Note If t...

Страница 9: ...mperature control knob F to between 40 C 65 C refer to colour screen whilst adjusting FROST PROTECTION If no frost protection is provided and frost is likely during a short absence from home leave the...

Страница 10: ...Engineer or in IE a Registered Gas Installer RGII should be consulted THE BOILER WILL NOT OPERATE IF THE PRESSURE HAS REDUCED TO LESS THAN 0 5 BAR UNDER THIS CONDITION In this case the following disp...

Страница 11: ...end of filling loop is hand tight 4 Turn the Domestic Hot Water DHW Inlet A blue handle to the horizontal position 5 Ensuring no leaks are seen gradually turn the filling loop handle blue B to the hor...

Страница 12: ...e is frozen at the most exposed point external to the building or where there is some obstruction to flow This could be at the open end of the pipe at a bend or elbow or where there is a dip in the pi...

Страница 13: ...LEAKS WITHANAKED FLAME CLEANING For normal cleaning simply dust with a dry cloth To remove stubborn marks and stains wipe with a damp cloth and finish off with a dry cloth DO NOT use abrasive cleanin...

Страница 14: ...ugh the following guide to identify any problems external to the boiler prior to requesting a service engineer s visit Should the problem be found to be other than with the appliance we reserve the ri...

Страница 15: ...e that the timer and Room Stat are switched on Check batteries in programmable room stats Rotate the Domestic Hot Water temperature control knob F clockwise Note that in cold weather it may be necessa...

Страница 16: ...wers are off Indicates that the timer or room stat is switched off Indicates that Central Heating has been switched off at the boiler Rotate Central Heating knob clockwise to switch on at the boiler C...

Страница 17: ...cates that the boiler is pre heating To switch pre heat Off see page 20 Indicates that a Service is due To reset see page 22 Reset Service Time ON MENU READY PREHEAT ON 80 C MENU READY TIMER OR ROOM T...

Страница 18: ...adiator temperature rotate the Central Heating knob E This screen will be shown To switch the heating off rotate the Central Heating knob E fully anti clockwise This screen will be shown EXIT 60O C 65...

Страница 19: ...ill be shown To change the room temperature set point only if outside sensor connected rotate the Central Heating knob E This screen will be shown To switch the boiler on rotate the Domestic Hot Water...

Страница 20: ...FF To switch preheat on press ON Press MENU and the following screen will be displayed Press MENU SHOW EFFICIENCY LEVEL HOT WATER PREHEAT ON OFF SERVICE COMPANY PHONE NUMBER SERVICE COMPANY NAME SELEC...

Страница 21: ...nd the following screen will be displayed Press select and a screen similar to the following will be displayed Press EXIT twice to return to normal operation EXIT SELECT MENU HOT WATER PREHEAT ON OFF...

Страница 22: ...until the following screen is displayed Press SELECT and the following screen is displayed Press MENU SHOW EFFICIENCY LEVEL HOT WATER PREHEAT ON OFF SERVICE COMPANY PHONE NUMBER SERVICE COMPANY NAME M...

Страница 23: ...23...